Publiko produktet
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
    Zurn

    Wilkins FCIS Connected Flood Control System

    The Flood Control Integrated System (FCIS) prevents flooding of a building, caused by the discharge from a catastrophically fouled Reduced Pressure Principal backflow preventer. The pre-wired FCIS package includes: • Reduced Pressure Principle backflow Preventer and Monitor Switch (Model 375MS or Model 975XL2MS) • Electronic Solenoid Time (Model EST) Signal Relay attached to a Solenoid Control Valve (Model ZW206) to shut-off the water supply
    Özellikler
    • The Flood Control Integrated System(FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375MS, 375AMS, 375ASTMS, or 975XL2MS), a Solenoid Control Valve(SCV) (Model ZW206), and an Electric Solenoid Timer (Model EST) and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor Switch that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The EST shall have an input voltage of 120 VAC, and shall be provided with outputs of 24 VAC and 120 VAC controlled by a user adjusted time delay relay. The EST shall be housed in a water-tight fiberglass NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and EST, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and Electronic Solenoid Timer assembled as a complete unit shall be the Zurn Wilkins FCIS.
    Teknik özellikler
    • Benzersiz ref.zurn-fcis
    • Ürün ailesiBackflow Preventers
    • Ürün grubuReduced Pressure Principle Assembly, Detector
    • TipObje (Tekil Nesne)
    • Yayınlanma tarihi2017-01-16
    • Baskı numarası3
    • Yükseklik (inç)27.25
    • Genişlik (inç)14.25
    • Derinlik (inç)43
    İlgili
    • Ana malzemeDuctile Iron
    • İkincil malzemePaslanmaz Çelik
    • Tasarım yeriBirleşik Devletler
    • Ağırlık net (Lbs)153
    Sınıflandırma
    • BIMobject kategorisiSıhhi tesisat - Valfler

    Bölge bulunurluk durumu

    Kuzey Amerika
    Anguilla
    Antigua ve Barbuda
    Aruba
    Bahamalar
    Barbados
    Belize
    Bermuda
    Birleşik Devletler
    Caribbean Netherlands
    Cayman Adaları
    Curaçao
    Dominik
    Dominik Cumhuriyeti
    El Salvador
    Grenada
    Grönland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    İngiliz Virjin Adaları
    Jamaika
    Kanada
    Kostarika
    Küba
    Martinique
    Meksika
    Montserrat
    Nikaragua
    Panama
    Porto Riko
    Saint Barthélemy
    Saint Kitts ve Nevis
    Saint Lucia
    Saint Martin
    Saint Pierre ve Miquelon
    Saint Vincent ve Grenadines
    Sint Maarten
    Trinidad ve Tobago
    Turks ve Caicos Adaları
    Virjin Adaları