    Wilkins FCIS Connected Flood Control System

    The Connected Flood Control System (Model FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375ASTW1, 375AW1, 375W1), a Solenoid Control Valve(SCV) (Model ZW206), and a Zurn Relief Valve Monitor and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI/CAN 61 & 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion-resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The Relief Valve Monitor shall have an input voltage of 120 VAC, and shall be provided with an output of 24 VDC controlled by a relay. The Relief Valve Monitor shall be housed in a water-tight NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and Relief Valve Monitor, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and assembled as a complete unit shall be the WILKINS FCIS.

    Compliance:

    • NSF Standard 61
    • NSF Standard 372
    • ASSE® Listed 1013
    • CSA® Certified B64.4
    • cUPC listed
    • UL listed
    • IPC listed
    • NPCC listed
    • Product USC Approved
    • Product FM Approved

    Features:

    • Ideal for installation in areas not immediately visible where undetected relief valve discharge could potentially cause catastrophic flooding and water damage.
    • Automatic shutoff of the water system reduces potential for costly flooding damage
    • 24/7 relief water discharge data provides secure real-time monitoring and notifications
    • Customizable water shutoff timer
    • The pre-wired FCIS package includes a Model 375W1, 375AW1 or 375ASTW1 
    • Reduced Pressure Principle Backflow Preventer and is attached to a Model ZW206 ACV Solenoid Control Valve.
    • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
    • Reduced Pressure Principle Assembly is AWWA compliant C511 (with gates only ) and C550
    สเปคสินค้า
    • Zurn Connected Flood Control Systems transmit data 24/7 to the Zurn plumbSMART™ web portal and mobile app. Proactively monitor your relief water discharge and optional system pressure data, receive real-time alerts for relief valve discharge occurrences, and access system data for trends and predictive maintenance anytime and anywhere. Zurn Connected Flood Control Systems are designed to prevent flooding of a building caused by discharge from a catastrophically fouled Reduced Pressure Principle backflow preventer. The pre-wired FCIS package includes a Model 375W1 Reduced Pressure Principle Backflow Preventer that detects relief valve discharge in real-time, and is attached to a Solenoid Control Valve to shut off the water supply when excessive discharge happens using a built-in relief valve position switch with adjustable time delay.

    สเปคสินค้าด้านเทคนิค
    • Unique ref.zurn-fcis
    • Product familyBackflow Preventers
    • กลุ่มผลิตภัณฑ์Reduced Pressure Principle Assembly, Detector
    • ประเภทวัตถุ (วัตถุชิ้นเดียว)
    • วันที่เผยเเพร่2025-09-02
    • หมายเลขฉบับ1
    • สูง (นิ้ว)27.25
    • กว้าง (นิ้ว)14.25
    • ความลึก (นิ้ว)43
    ลิงค์
    สิ่งที่เกี่ยวข้อง
    • วัสดุหลักDuctile Iron
    • วัสดุรองStainless steel
    • ออกเเบบโดยสหรัฐอเมริกา
    • น้ำหนัก153
    การจำแนกประเภท
    • หมวดหมู่ BIMobjectประปา - วาล์ว

    พื้นที่การขาย

    อเมริกาเหนือ
    กรีนแลนด์
    แซ็ง-บาร์เตเลมี
    กวาเดอลูป
    กัวเตมาลา
    กือราเซา
    เกรเนดา
    คอสตาริกา
    คิวบา
    เครือรัฐดอมินีกา
    แคนาดา
    จาเมกา
    ซินต์มาร์เติน
    เซนต์คิตส์และเนวิส
    เซนต์ลูเซีย
    เซนต์วินเซนต์และเกรนาดีนส์
    แซงปีแยร์และมีเกอลง
    แซงมาร์แตง
    ตรินิแดดและโตเบโก
    นิการากัว
    เนเธอร์แลนด์แคริบเบียน
    บาร์เบโดส
    บาฮามาส
    เบลีซ
    เบอร์มิวดา
    ปานามา
    เปอร์โตริโก
    มอนต์เซอร์รัต
    มาร์ตินีค
    เม็กซิโก
    สหรัฐอเมริกา
    สาธารณรัฐโดมินิกัน
    หมู่เกาะเคย์แมน
    หมู่เกาะเติกส์และหมู่เกาะเคคอส
    หมู่เกาะบริติชเวอร์จิน
    หมู่เกาะเวอร์จินของสหรัฐ
    อารูบา
    เอลซัลวาดอร์
    แองกวิลลา
    แอนติกาและบาร์บูดา
    ฮอนดูรัส
    เฮติ
    Common.Footer.ValueProp.Image.AltText

    แอปออกแบบสำหรับ Revit

    ดาวน์โหลด Design App.Common.Title

    รับพื้นที่เพื่อเข้าถึงวัตถุใหม่ๆ ได้ง่ายขึ้น จัดเก็บ Revit families ของคุณ และทำงานร่วมกับทีมของคุณ

    • เครื่องหมายถูกทำงานโดยตรงกับวัตถุ BIM ข้าง Revit
    • เครื่องหมายถูก พื้นที่จัดเก็บข้อมูลบนคลาวด์ 2GB - จัดเก็บเนื้อหา Revit ของคุณ
    • เครื่องหมายถูก รับ LCA คาร์บอนในตัว (A1-A3) โดยตรงจาก Revit