myRoom XC Guestroom Wireless Processor
myRoom XC Guestroom Wireless Processor
    Lutron Electronics

    myRoom XC Guestroom Wireless Processor

    The guestroom wireless processor integrates Clear Connect – Type X devices (such as Ketra loads) with Clear Connect – Type A devices (such as Pico wireless controls and Radio Powr Savr sensors).

    ติดต่อกับ Lutron Electronics

    สเปคสินค้า
    • Each guestroom wireless processor can communicate with the following: 

      • Clear Connect - Type X devices (100 maximum)– Commercial Ketra Type X loads– Sunnata dimmers / switches / keypads– Lumaris RGB + Tunable White tape light – Athena wireless nodes– Rania D2 

      • Clear Connect - Type A devices (50 maximum)– Pico wireless controls– Radio Powr Savr occupancy/vacancy sensors (15 maximum) Features 

      • Powered by an IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ power supply, Lutron model L-POEI-BL or by others (sold separately). 

      • Timeclock scheduling of daily events. 

      • Connects to the network via an Ethernet connection. 

      • Local device operation will continue to function if internet connection is lost.

      Specifications 

      Regulatory Approvals • cULus • FCC • IC • NOM • IFTEL 

      PoE Power • Processor is an IEEE 802.3af compliant Class 1 device; typical 1.5 W (max 4.0 W) • 48 V- 100 mA (IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+) • Compatible power supply: L-POEI-BL available for purchase separately, or IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ supply by others 

      Environment • Operating temperatures 32 °F to 104 °F (0 °C to 40 °C) • Relative humidity: 0% to 90% non-condensing • For indoor use only 

      ESD Protection • Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. 

      Surge Protection • Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits. 

      Power Failure • 10-year power failure memory: Should the power be interrupted, the wireless processor will return to its previous state prior to the interruption when power is restored.

      Mounting • The guestroom wireless processor can be recess-mounted or wall-mounted using the included recess bracket or junction box bracket in a nonmetal ceiling tile or drywall. When mounting on a 4 in x 4 in (102 mm x 102 mm) junction box, a mud ring (not supplied) must be used. • The guestroom wireless processor can also be shelf-mounted using the L-SMNT-WH (sold separately). • The guestroom wireless processor and Clear Connect - Type X devices must be mounted 5 ft (1.5 m) away from wireless interference sources like microwaves, Wireless Access Points (WAP), etc. • Do not install the guestroom wireless processor in metallic enclosures. • Do not install the guestroom wireless processor above metal ceilings or tiles with metal backing. 

      Wiring • Use Cat5e minimum cable. Maximum length is 328 ft (100 m) from router to processor. Each wireless processor needs to have a home run Ethernet connection back to the PoE supply. • PoE wiring must be kept internal to the building. Do not run PoE wiring outdoors

    สเปคสินค้าด้านเทคนิค
    • Unique ref.lutron-myroomxc-rf2-gcu
    • Product familyLighting Controls
    • กลุ่มผลิตภัณฑ์myRoom XC
    • ประเภทวัตถุ (วัตถุชิ้นเดียว)
    • วันที่เผยเเพร่2026-04-17
    • หมายเลขฉบับ1
    • สูง (นิ้ว)4.04
    • กว้าง (นิ้ว)4.04
    • ความลึก (นิ้ว)1.17
    สิ่งที่เกี่ยวข้อง
    • วัสดุหลักPlastic
    การจำแนกประเภท
    • หมวดหมู่ BIMobjectอุปกรณ์ไฟฟ้า - ระบบควบคุม / ตู้ควบคุม

    สินค้าใกล้เคียง

    Common.Footer.ValueProp.Image.AltText

    แอปออกแบบสำหรับ Revit

    ดาวน์โหลด Design App.Common.Title

    รับพื้นที่เพื่อเข้าถึงวัตถุใหม่ๆ ได้ง่ายขึ้น จัดเก็บ Revit families ของคุณ และทำงานร่วมกับทีมของคุณ

    • เครื่องหมายถูกทำงานโดยตรงกับวัตถุ BIM ข้าง Revit
    • เครื่องหมายถูก พื้นที่จัดเก็บข้อมูลบนคลาวด์ 2GB - จัดเก็บเนื้อหา Revit ของคุณ
    • เครื่องหมายถูก รับ LCA คาร์บอนในตัว (A1-A3) โดยตรงจาก Revit