    The Flood Control Integrated System (FCIS) prevents flooding of a building, caused by the discharge from a catastrophically fouled Reduced Pressure Principal backflow preventer. The pre-wired FCIS package includes: • Reduced Pressure Principle backflow Preventer and Monitor Switch (Model 375MS or Model 975XL2MS) • Electronic Solenoid Time (Model EST) Signal Relay attached to a Solenoid Control Valve (Model ZW206) to shut-off the water supply
    Specifikation
    • The Flood Control Integrated System(FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375MS, 375AMS, 375ASTMS, or 975XL2MS), a Solenoid Control Valve(SCV) (Model ZW206), and an Electric Solenoid Timer (Model EST) and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor Switch that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The EST shall have an input voltage of 120 VAC, and shall be provided with outputs of 24 VAC and 120 VAC controlled by a user adjusted time delay relay. The EST shall be housed in a water-tight fiberglass NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and EST, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and Electronic Solenoid Timer assembled as a complete unit shall be the Zurn Wilkins FCIS.
    Teknisk specifikation
    • Unik ref.zurn-fcis
    • ProduktfamiljBackflow Preventers
    • ProduktgruppReduced Pressure Principle Assembly, Detector
    • TypObjekt (enstaka objekt)
    • Publiceringsdatum2025-09-02
    • Edition nummer1
    • Höjd (tum)27.25
    • Bredd (tum)14.25
    • Djup (tum)43
    Relaterad
    • HuvudmaterialDuctile Iron
    • Sekundärt materialRostfritt stål
    • Designad iUSA
    • Vikt netto (lbs)153
    Klassificering
    • BIMobjektkategoriRörläggning - Ventiler

    Region tillgänglighet

    Nordamerika
    Amerikanska Jungruöarna
    Anguilla
    Antigua och Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    British Virgin Islands
    Caymanöarna
    Costa Rica
    Curaçao
    Dominica
    Dominikanska republiken
    El Salvador
    Grenada
    Grönland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Kanada
    Karibiska Nederländerna
    Kuba
    Martinique
    Mexiko
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Christopher och Nevis
    Saint Lucia
    Saint Vincent och Grenadinerna
    Saint-Barthélemy
    Saint-Martin
    Saint-Pierre-et-Miquelon
    Sint Maarten
    Trinidad och Tobago
    Turks och Caicos Islands
    USA
    Common.Footer.ValueProp.Image.AltText

    Design App för Revit

    Ladda familjer direkt till din Revit-modell med ett klick

    Få en plats för att enklare komma åt nya objekt, lagra dina Revit-familjer och samarbeta med ditt team.

    • BockmarkeringArbeta direkt med BIM-objekt bredvid Revit
    • Bockmarkering 2 GB molnlagring - lagra ditt Revit-innehåll
    • Bockmarkering Få inbyggd kol-LCA (A1-A3) direkt från Revit