Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
    Wilkins

    Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer

    The Reduced Pressure Principle Backflow Preventer shall be certified to NSF/ANSI/CAN 61 and 372, shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The assembly shall be configurable to include a sensor to monitor excessive water discharge from the relief valve for flood detection. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL2.

    Features:

    • Easy access to first check simplifies debris removal
    • Repair kit allows for a quick fix instead of a full replacement
    • Entire unit serviceable in line
    • Stainless steel shutoff handles are corrosion resistant
    • Wye pattern design provides separate access to checks and relief valve for reduced labor costs

    Keywords: Backflow Preventer, hazard protection, Reduced Pressure Principle, Zurn Wilkins 975XL2, Reduced Pressure Principle Backflow Preventer, Reduced Pressure Backflow Preventer, relief valve, check valve, reduced pressure principle backflow prevention assembly, reduced pressure zone backflow preventer, backflow relief valve, backflow pressure relief valve, zurn 975xl2, wilkins zurn 975xl2

    Teknisk specifikation
    • Unik ref.zurn-975xl2-075-2
    • ProduktfamiljBackflow Preventers
    • ProduktgruppReduced Pressure Principle Assembly
    • TypObjekt (enstaka objekt)
    • Publiceringsdatum2025-09-02
    • Edition nummer1
    • Höjd (tum)8.5
    • Bredd (tum)6.5
    • Djup (tum)12
    Relaterad
    • HuvudmaterialBronze
    • Designad iUSA
    • Vikt netto (lbs)12
    Klassificering
    • BIMobjektkategoriRörläggning - Ventiler
    • IFC klassificeringVentil
    • Uniclass 2015 kodPr_65_54_94_72
    • Uniclass 2015 beskrivningReduced pressure zone valves
    • CSI MasterFormat 2014 Kod40 05 67
    • CSI MasterFormat 2014 TitelSpecialized Pressure and Flow-Control Valves
    • OmniClass nummer23-27 31 47
    • OmniClass TitelPressure Regulating Valves

    Region tillgänglighet

    Nordamerika
    Amerikanska Jungruöarna
    Anguilla
    Antigua och Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    British Virgin Islands
    Caymanöarna
    Costa Rica
    Curaçao
    Dominica
    Dominikanska republiken
    El Salvador
    Grenada
    Grönland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Kanada
    Karibiska Nederländerna
    Kuba
    Martinique
    Mexiko
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Christopher och Nevis
    Saint Lucia
    Saint Vincent och Grenadinerna
    Saint-Barthélemy
    Saint-Martin
    Saint-Pierre-et-Miquelon
    Sint Maarten
    Trinidad och Tobago
    Turks och Caicos Islands
    USA
    Common.Footer.ValueProp.Image.AltText

    Design App för Revit

    Ladda familjer direkt till din Revit-modell med ett klick

    Få en plats för att enklare komma åt nya objekt, lagra dina Revit-familjer och samarbeta med ditt team.

    • BockmarkeringArbeta direkt med BIM-objekt bredvid Revit
    • Bockmarkering 2 GB molnlagring - lagra ditt Revit-innehåll
    • Bockmarkering Få inbyggd kol-LCA (A1-A3) direkt från Revit