Wilkins 475STDA Reduced Pressure Detector Assembly, 4" to 10", Lead-Free*
Wilkins 475STDA Reduced Pressure Detector Assembly, 4" to 10", Lead-Free*
Wilkins 475STDA Reduced Pressure Detector Assembly, 4" to 10", Lead-Free*
    Wilkins

    Wilkins 475STDA Reduced Pressure Detector Assembly, 4" to 10", Lead-Free*

    The Reduced Pressure Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1047, and supplied with full port OS & Y gate valves. The main body and access cover shall be 304L Stainless Steel, the seat ring and check valve shall be NORYL™, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Backflow Prevention Assembly shall be a WILKINS Model 475STDA

    Compliance:

    • NSF Standard 61
    • NSFStandard372
    • ASSE 1047
    • C511
    • CSA B64.4
    • UL
    • NPCC
    • FM Approved

    Features:

    • Superior stainless steel body resists corrosion and extends the life of the product
    • Small, compact footprint allows for direct drop-in replacement
    • Time-tested check and relief valve components ensure easy maintenance and more water system uptime
    • Patented compound checks provide ultra-low pressure drop as documented by approval authorities, reducing the need for a booster pump
    • Patented AR spool for drop-in replacements, matching lay-lengths of common n-pattern valves
    • AR spool maintains agency approvals when installed by the factory
    • Backflow setter eliminates the need for concrete thrust blocks, allowing for easier installation and lower cost
    • Available in sizes 4 in. through 10 in.

    keywords: backflow preventer, backflow, back flow preventer, back flow valve, backflow preventer valve, backflow preventers, backflow valve, backflow device, backflow prevention device, backflow prevention, n-pattern, double check, 475, 475stda, reduced pressure detector assembly,10-475STDA,4-475STDA,6-475STDA,8-475STDA

    Teknisk specifikation
    • Unik ref.zurn-475STDA
    • ProduktfamiljBackflow Preventers
    • ProduktgruppReduced Pressure Principle Assembly, Detector
    • TypObjekt (enstaka objekt)
    • Publiceringsdatum2025-09-02
    • Edition nummer1
    Relaterad
    • HuvudmaterialRostfritt stål
    • Sekundärt materialRostfritt stål
    • Designad iUSA
    Klassificering
    • BIMobjektkategoriRörläggning - Ventiler

    Region tillgänglighet

    Nordamerika
    Amerikanska Jungruöarna
    Anguilla
    Antigua och Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    British Virgin Islands
    Caymanöarna
    Costa Rica
    Curaçao
    Dominica
    Dominikanska republiken
    El Salvador
    Grenada
    Grönland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Kanada
    Karibiska Nederländerna
    Kuba
    Martinique
    Mexiko
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Christopher och Nevis
    Saint Lucia
    Saint Vincent och Grenadinerna
    Saint-Barthélemy
    Saint-Martin
    Saint-Pierre-et-Miquelon
    Sint Maarten
    Trinidad och Tobago
    Turks och Caicos Islands
    USA
    Common.Footer.ValueProp.Image.AltText

    Design App för Revit

    Ladda familjer direkt till din Revit-modell med ett klick

    Få en plats för att enklare komma åt nya objekt, lagra dina Revit-familjer och samarbeta med ditt team.

    • BockmarkeringArbeta direkt med BIM-objekt bredvid Revit
    • Bockmarkering 2 GB molnlagring - lagra ditt Revit-innehåll
    • Bockmarkering Få inbyggd kol-LCA (A1-A3) direkt från Revit