System dimensions and features
» Design depths: Frame/glazing bars 77 mm, sash 84 mm
» Face widths: Frame 70–120 mm, glazing bars 114-194 mm, sash hidden
» Minimum, combined face width: 81 mm
» Max. glass/filling strength: Frame 54 mm, sash 64 mm
» Max. sash weight: 130 kg
» Max. sash height: 2,400 mm
» Highly thermally insulated 3-chamber aluminium composite system
» Thermal insulation: Uf [101] = 1.0 W/m2K
» U value adjustment through modular insulation zone construction
» Air permeability: 4
» Driving rain tightness: 9A
» Wind load resistance: C5/B5
» Soundproofing categories: 1–4
» Burglary resistance: RC 2
Configuration options and design
» System security using exposed (heroal WF 100) and concealed (heroal WF 100 i) heroal aluminum sliding bar fittings
» Narrow face widths specially designed for use in façade system heroal C 50
» Sash range also for plastic fitting systems
» System-compatible with window system heroal W 77 and façade system heroal C 50
» Colour scheme in high-quality heroal hwr powder coating