Wilkins 950XLT2 Double Check Backflow Preventer
Wilkins 950XLT2 Double Check Backflow Preventer
Wilkins 950XLT2 Double Check Backflow Preventer
Wilkins 950XLT2 Double Check Backflow Preventer
Wilkins 950XLT2 Double Check Backflow Preventer
    Wilkins

    Wilkins 950XLT2 Double Check Backflow Preventer

    The Double Check Type Backflow Preventer shall be certified to NSF/ANSI 61, shall be ASSE Listed 1015, rated to 180° F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be NORYL™ and the seat disc elastomers shall be SILICONE. The first and second check shall be located at a 45° angle and accessible for maintenance from the top of the device, without removing the device from the line. Each check shall have separate access covers and test cocks shall be accessible from the top of the device. Test cocks shall be protected from debris by a plug. The Double Check Type Backflow Preventer shall be a ZURN WILKINS Model 950XLT2.

    Compliance:

    • ASSE® Listed 1015
    • cUPC® Listed
    • CSA® Certified B64.5
    • AWWA Compliant C510
    • USC Approved
    • NSF/ANSI/CAN 61 & 372

    Features:

    • Sizes: 3/4", 1", 1 1/4", 1 1/2", 2"
    • Maximum working water pressure 175 PSI
    • Maximum working water temperature 180°F
    • Hydrostatic test pressure 350 PSI
    • End connections Threaded ANSI B1.20.1

    Keywords: Double Check Backflow Preventer, double check backflow preventer zurn wilkins, wilkins backflow preventer, double check backflow preventer zurn installation, ,zurn backflow preventer parts

    Specifikim
    • Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. A test cock plug is provided to protect against fouling caused by insects, dirt and debris. Assembly shall provide protection where a potential non-health hazard exists.

    Specifikime teknike
    • Referencë unikezurn-950xlt2
    • Familja e produkteveBackflow Preventers
    • Grupi i produkteveDouble Check Assembly
    • LlojiObjekt (një objekt të vetëm)
    • Data e botimit2025-09-02
    • Numri i botimit1
    Të ngjashme
    • Materiali kryesorBronze
    • Materiali dytësorBronze
    • Projektuar nëShtetet e Bashkuara
    Klasifikimi
    • Kategoria BIMobjectPajisje hidraulike - Valvul

    Rajoni i disponueshëm

    North America
    Anguilla
    Antigua dhe Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Dominica
    El Salvador
    Grenada
    Grenlandë
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Ishujt e Virgjër Britanikë
    Ishujt e Virgjër të SHBA
    Ishujt Kajman
    Kanadë
    Karaibe Holandë
    Kolektiviteti i Shën Martinit
    Kosta Rika
    Kubë
    Kuraçao
    Martinique
    Meksikë
    Montserrat
    Nikaragua
    Panama
    Porto Riko
    Republika Domenikane
    Saint-Barthélemy
    Shën Kitts dhe Nevis
    Shën Lucia
    Shën Pierre dhe Miquelon
    Shën Vincent dhe Grenadinet
    Shtetet e Bashkuara
    Sint Maarten
    Trinidad dhe Tobago
    Turks dhe Caicos Islands
    Xhamaika
    Common.Footer.ValueProp.Image.AltText

    Aplikacion dizajnimi për Revit

    Ngarkoni familjet direkt në modelin tuaj Revit me një klik të vetëm

    Merrni një vend për të hyrë më lehtë në objekte të reja, ruani familjet tuaja Revit dhe bashkëpunoni me ekipin tuaj.

    • Shenjë টিকPunoni drejtpërdrejt me objekte BIM pranë Revit
    • Shenjë টিক 2 GB hapësirë ruajtje në Cloud - ruani përmbajtjen tuaj Revit
    • Shenjë টিক Merrni LCA e karbonit të mishëruar (A1-A3) direkt nga Revit