Double Check Detector Assemblies - 007M1DCDA
Watts

Double Check Detector Assemblies - 007M1DCDA

The Model 007M1DCDA Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This device assembly is primarily used on commercial fire sprinkler systems where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Maximum Working Pressure: 175psi (12.06 bar).

  • Compact design for easy installation in tight places
  • Can replace seats, seat discs, and auxiliary line and components in the field
  • Auxiliary bypass line detects costly underground water leaks or illegal taps
  • Single cover, top-entry design allows for convenient access for maintenance


Specifikim
  • Keywords: assembly, backflow, backflow preventer valve, backflow valve, bronze body, bypass, cast iron, check valve, cover, dcda, detector, double, double check, doublecheck, epoxy coated, meter, pex crimping tools, pex tools, pressure valve, pressure zone valve, preventer, reduced pressure valve, repairkit, replacement, rpza, shut-off, steam, steamtrap, trap, valve, vlv, watts regulator, plumbing, drains, drainage
Specifikime teknike
  • Referencë unikeDouble-Check-Detector-Assemblies-007M1DCDA
  • Familja e produktevePlumbing & Flow Control Solutions
  • Grupi i produkteveBackflow Preventers > Double Check Detector Assemblies
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2019-01-01
  • Numri i botimit1
Të ngjashme
  • Materiali kryesorBronze
  • Projektuar nëShtetet e Bashkuara
  • Prodhuar nëShtetet e Bashkuara
Klasifikimi
  • Kategoria BIMobjectPajisje hidraulike - Valvul
  • IFC classificationValvul
  • Emrin UNSPSCValves
  • UNSPSC code401416
  • Uniclass 2015 CodePr_65_54_95_05
  • Uniclass 2015 PërshkrimBackflow prevention devices
  • CSI MasterFormat 2014 Code40 05 67.16
  • CSI MasterFormat 2014 TitleDouble Check Valve Assembly Backflow Preventers for Process Service
  • OmniClass Number23-27 31 11
  • OmniClass TitleBackflow Preventors
  • CSI UniFormat II CodeD20
  • CSI UniFormat II TitlePLUMBING

Rajoni i disponueshëm

North America
Kanadë
Shtetet e Bashkuara
Common.Footer.ValueProp.Image.AltText

Aplikacion dizajnimi për Revit

Ngarkoni familjet direkt në modelin tuaj Revit me një klik të vetëm

Merrni një vend për të hyrë më lehtë në objekte të reja, ruani familjet tuaja Revit dhe bashkëpunoni me ekipin tuaj.

  • Shenjë টিকPunoni drejtpërdrejt me objekte BIM pranë Revit
  • Shenjë টিক 2 GB hapësirë ruajtje në Cloud - ruani përmbajtjen tuaj Revit
  • Shenjë টিক Merrni LCA e karbonit të mishëruar (A1-A3) direkt nga Revit