Lead Free* Stainless Steel Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor - 2 1/2 - 10 IN Sizes - LFC500-FS
Lead Free* Stainless Steel Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor - 2 1/2 - 10 IN Sizes - LFC500-FS
Lead Free* Stainless Steel Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor - 2 1/2 - 10 IN Sizes - LFC500-FS
Lead Free* Stainless Steel Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor - 2 1/2 - 10 IN Sizes - LFC500-FS
    Ames Fire & Waterworks

    Lead Free* Stainless Steel Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor - 2 1/2 - 10 IN Sizes - LFC500-FS

    Series LFC500 Lead Free* reduced pressure detector assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

    This series help stop the reverse flow of fire protection system substances being pumped or siphoned into the potable water supply. A meter incorporated to detect ground leaks and unauthorized illegal taps greatly reduces annual water expenses. It is 70% lighter than traditional designs and is ideal for health hazard cross-connections, such as on fire sprinkler systems. Check with local water authorities for installation requirements.

    The TS-OSY model is equipped with a factory installed, durable, and robust supervisory switch (UL Certified, Safety Signaling, Control No. 3L38) for tamper detection. The alert sounds when attempts are made to remove the switch from the gate valve or to close the valve. Wiring of the supervisory switch to a fire alarm control panel is required.

    Cпецификация
    • Features

      • Sensor on the relief valve for flood detection
      • Lead Free* stainless steel body with stainless steel internal parts
      • Protects against backsiphonage, backpressure, and the fouling of either check valve
      • Detects loss due to underground water leaks or unauthorized water usage
      • Patented link check provides low pressure loss
      • Flood alert feature activated with add-on connection kit, compatible with BMS and cellular communication
      • Integrated supervisory switch (UL Certified, Safety Signaling, Control No. 3L38) on outside stem and yoke resilient seated gate valve
    Техническая спецификация
    • Уникальная ссылкаlfc500-fs
    • Тип продукцииPlumbing & Flow Control Solutions
    • Группа продукцииBackflow Prevention
    • ТипОбъект (один объект)
    • Дата публикации2024-02-13
    • Номер версии1
    Связанные
    • Основной материалНержавеющая сталь
    • Разработано вСоединенные Штаты Америки
    • Страна-производительСоединенные Штаты Америки
    Классификация
    • Категория BIMobjectСантехника - Клапаны
    • Классификация IFCКлапан
    • Название по ССКПУ ООНValves
    • Код ССКПУ ООН401416
    • Код Uniclass 2015Pr_65_54_40_62
    • Описание Uniclass 2015Plastics isolating valves
    • Код CSI MasterFormat 201440 05 67
    • Заголовок CSI MasterFormat 2014Specialized Pressure and Flow-Control Valves
    • Номер OmniClass23-27 31 00
    • Наименование OmniClassValves
    • Код CSI UniFormat IIC1030
    • Заголовок CSI UniFormat IIFittings

    Доступно в регионах:

    Северная Америка
    Канада