Publique seus produtos
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market
    Caleffi

    ThermoSetter™ Thermal Balancing Valve (thermal disinfection) - NA Market

    Traduzido pelo Google,

    A válvula de balanceamento térmico ajustável ThermoSetter™ é usada para balanceamento automático de circuitos de recirculação em sistemas de água quente sanitária, para acelerar o fornecimento de água quente, reduzir o desperdício de água e economizar energia. O cartucho de balanceamento termostático interno modula automaticamente o fluxo para garantir uma temperatura constante no sistema de tubulação de recirculação. A Série 116A possui botão de ajuste de 35°C a 60°C (95°F a 140°F), tamanhos ½", ¾"; 95°F a 150°F (35°C a 65°C), tamanhos 1", indicação de escala de temperatura de 1¼". Uma válvula de retenção integral para evitar a termo-sifão do circuito é padrão nos tamanhos 1/2” e 3/4” e é um acessório opcional nos tamanhos 1” e 1-1/4”.
    As séries 1162xx e 1166xx estão disponíveis com um bypass de “desinfecção”
    cartucho, para uso em sistemas projetados para realizar desinfecção térmica
    para prevenção da Legionella. Quando o cartucho de desinfecção detecta 70°C (160°F)
    -1162xx, ou 140°F (60°C) -1166xx, água (2 opções de temperatura disponíveis),
    indicando o modo de controle de desinfecção, ele abre automaticamente um caminho de fluxo de desvio para
    permitir fluxo suficiente para que a desinfecção ocorra. Quando a temperatura cai novamente
    para a faixa normal, o cartucho de desvio de desinfecção fecha para retornar o controle do fluxo
    ao cartucho de balanceamento.
    A Série 1163xx também está disponível com uma válvula de “desinfecção” controlada
    por um atuador termoelétrico de retorno por mola de 24 V, em vez de termostaticamente, assim
    permitindo que o modo de desinfecção térmica seja controlado remotamente por uma automação
    sistema.
    O ThermoSetter série 116A está disponível pré-montado com válvula esférica de passagem completa em latão Caleffi com baixo teor de chumbo para isolamento. Os tamanhos de conexão de 1/2 e 3/4 de polegada são pré-montados com a válvula de esfera de baixo chumbo da série Caleffi 290030. Os tamanhos de conexão de 1 e 1-1/4 polegadas são pré-montados com a válvula de esfera de baixo chumbo da série Caleffi NA108. Os códigos de produto para ThermoSetters 116A pré-montados com válvulas de isolamento podem ser encontrados na página 3 para 1/2 e 3/4 polegada e na página 5 para 1 e 1-1/4 polegada.
    A válvula está em conformidade com NSF-ANSI-CAN 61 (180°F (82°C) Comercial Quente) conforme certificado
    pela ICC-ES e está em conformidade com NSF-ANSI 372, baixo avanço e códigos IPC e UPC ou
    use de acordo com os códigos de encanamento dos EUA e do Canadá, conforme certificado pela ICC-ES.

    Visite bim.caleffi.com para se manter atualizado.

    Especificação
    • Series 1161
      Thermal balancing valve for domestic hot water recirculation circuits. Dezincification resistant low-lead brass body (<0.25% Lead content) certified to NSF/ANSI 372 by ICC-ES, file PMG-1360. Certified to NSF/ANSI 61 (180°F/82°C Commercial Hot), by ICC-ES, file PMG-1512. Sizes ½" and ¾": sweat, press. PEX crimp and PEX expansion union connections. PEX crimp fittings must
      comply with ASTM F 1807. PEX expansion fittings must comply with ASTM F 1960. Sizes 1" and 1¼" with NPT female connections. Adjustable thermostatic cartridge. Peroxide-cured EPDM hydraulic seals. Temperature gauge/probe dry-well Ø 10 mm. Maximum working pressure 230 psi (16 bar). Maximum differential pressure 15 psi (1 bar). Adjustment temperature range 95°F to 140°F (35°C-60°C), sizes ½", ¾"; 95°F to 150°F (35°C to 65°C), sizes 1", 1¼". Flow rating: 2.1 Cv (1.8 Kv) maximum, 0.23 Cv (0.2 Kv) minimum, 0.52 Cv (0.45 Kv) design. Equipped with: ABS adjustment knob with temperature adjustment scale for manual setting and tamper-proof adjustment locking screw. Provide with optional outlet temperature gauge with 30°F to 180°F (0°C-80°C) temperature scale. For sizes ½" and ¾", provided with inlet flow check valve. For sizes 1" and 1¼", provide with optional check valve. For sizes ½" and ¾", provide with optional inlet and outlet isolation ball valves, code 290030, separately sourced, field installed. For sizes 1" and 1¼", provide with optional inlet and outlet low-lead brass full-port ball valves, NPT female x NPT female, for isolation, factory-assembled, or separately-sourced, Code NA108 series, with separately-sourced low-lead close nipples. Pre-formed insulation shell is available for field installation.

      Series 1162 & 1166
      Thermal balancing valve for domestic hot water recirculation circuits with thermostatic by-pass valve for thermal disinfection function. Dezincification resistant low-lead brass body (<0.25% Lead content) certified to NSF/ANSI 372 by ICC-ES, file PMG-1360. Certified to NSF/ANSI 61 (180°F/82°C Commercial Hot), by ICC-ES, file PMG-1512. Sizes ½" and ¾": sweat, press. PEX crimp and PEX expansion union connections. PEX crimp fittings must comply with ASTM F 1807. PEX expansion fittings must comply with ASTM F 1960. Sizes 1" and 1¼" with NPT female connections. Adjustable thermostatic cartridge. Peroxide-cured EPDM hydraulic seals. Temperature gauge/probe dry-well Ø 10 mm. Maximum working pressure 230 psi (16 bar). Maximum differential pressure 15 psi (1 bar). Adjustment temperature range 95°F to 140°F (35°C-60°C), sizes ½", ¾"; 95°F to 150°F (35°C to 65°C), sizes 1", 1¼". Disinfection temperature 160°F (70°C) for 1162 series, 140°F (60°C) for 1166 series. Closing temperature 170°F (75°C) for 1162 series, 150°F (65°C) for 1166 series. Flow rating: 2.1 Cv (1.8 Kv) maximum, 1.2 Cv (1.0 Kv) disinfection, 0.23 Cv (0.2 Kv) minimum, 0.52 Cv (0.45 Kv) design. Equipped with: ABS adjustment knob with temperature adjustment scale for manual setting and tamper-proof adjustment locking screw, outlet temperature gauge with 30°F to 180°F (0°C-80°C) temperature scale. For sizes ½" and ¾", provided with inlet flow check valve. For sizes 1" and 1¼", provide with optional check valve. For sizes ½" and ¾", provide with optional inlet and outlet isolation ball valves, code 290030, separately sourced, field installed. For sizes 1" and 1¼", provide with optional inlet and outlet low-lead brass full-port ball valves, NPT female x NPT female, for isolation, factory-assembled, or separately-sourced, Code NA108 series, with separately-sourced low-lead close nipples. Pre-formed insulation shell is available for field installation.

      Series 1163
      Thermal balancing valve for domestic hot water recirculation circuits with by-pass valve for thermal disinfection function with optional code 656 series thermo-electric actuator. Dezincification resistant low-lead brass body (<0.25% Lead content) certified to NSF/ANSI 372 by ICC-ES, file PMG-1360. Certified to NSF/ANSI 61 (180°F/82°C Commercial Hot), by ICC-ES, file PMG-1512. Sizes ½" and ¾": sweat, press. PEX crimp and PEX expansion union connections. PEX crimp fittings must comply with ASTM F 1807. PEX expansion fittings must comply with ASTM F 1960. Sizes 1" and 1¼" with NPT female connections. Adjustable thermostatic cartridge. Peroxide-cured EPDM hydraulic seals. Temperature gauge/probe dry-well Ø 10 mm. Maximum working pressure 230 psi (16 bar). Maximum differential pressure 15 psi (1 bar). Adjustment temperature range 95°F to 140°F (35°C-60°C), sizes ½", ¾"; 95°F to 150°F (35°C to 65°C), sizes 1", 1¼". Disinfection temperature 160°F (70°C). Closing temperature 170°F (75°C). Flow rating: 2.1 Cv (1.8 Kv) maximum, 1.2 Cv (1.0 Kv) disinfection, 0.23 Cv (0.2 Kv) minimum, 0.52 Cv (0.45 Kv) design. Equipped with: ABS adjustment knob with temperature adjustment scale for manual setting and tamper-proof adjustment locking screw, outlet temperature gauge with 30°F to 180°F (0°C-80°C) temperature scale. For sizes ½" and ¾", provided with inlet flow check valve. For sizes 1" and 1¼", provide with optional check valve. For sizes ½" and ¾", provide with optional inlet and outlet isolation ball valves, code 290030, separately sourced, field installed. For sizes 1" and 1¼", provide with optional inlet and outlet low-lead brass full-port ball valves, NPT female x NPT female, for isolation, factory-assembled, or separately-sourced, Code NA108 series, with separately-sourced low-lead close nipples. Pre-formed insulation shell is available for field installation.

    Especificação técnica
    • Ref. única116A
    • Família de produtoPLUMBING
    • Grupo de produtosNorth America
    • TipoObjeto (objeto único)
    • Data de publicação2019-03-12
    • Número da edição3
    Afins
    • Material principalLatão
    • Material secundárioAço inox
    • Desenhado emItaly
    • Fabricado emItaly
    Classificação
    • Categoria BIMobjectHidráulica - Válvulas
    • Classificação IFCVálvula
    • Código ETIMEC011516
    • Nome ETIMThermostatic control valve, hot tap water
    • Nome UNSPSCValves
    • Código UNSPSC401416
    • Código Uniclass 2015Ss_40_15_75_75
    • Descrição Uniclass 2015Sanitary accessory systems
    • CSI MasterFormat 2014 Code22 00 00
    • Título CSI MasterFormat 2014Plumbing
    • Número OmniClass23-27 31 13
    • Título OmniClassBalancing Valves
    • CSI UniFormat II CodeD20
    • Título UniFormat II da CSIPLUMBING

    Disponibilidade regional

    América do Norte
    Canada
    United States
    Common.Footer.ValueProp.Image.AltText

    Aplicativo Design para Revit

    Carregue famílias diretamente no seu modelo Revit com um clique

    Tenha um local para acessar novos objetos com mais facilidade, armazenar suas famílias Revit e colaborar com sua equipe.

    • Marca de seleçãoTrabalhe diretamente com objetos BIM próximos ao Revit
    • Marca de seleção 2GB de armazenamento na nuvem - armazene seu conteúdo Revit
    • Marca de seleção Obtenha o LCA de carbono incorporado (A1-A3) diretamente do Revit