STANDARD TECHNICAL CHARACTERISTICS:
Power supply 230 VAC single phase for the main supply
(Do not connect to a floating network or to high impedance earthed industrial distribution network)
Barrier arm length:
BLG 77 H : L = 5.080 m - H = 3.356 m
BLG 77 M : L = 5.080 m - H = 2.137 m.
BLG 77 L : L = 6.350 m - H = 2.137 m.
BLG 77 HL : L = 6.350 m - H = 2.746 m.
Opening time 10 seconds.
Tip support Electromagnetic locking tip support.
Motor 560 W Three phase
Frequency 50 Hz
Resistance of the barrier to wind (even if opened)
BLG 77 L & BLG 77 M : 120 km/h.
BLG 77 H & BLG 77 HL : 100 km/h.
Strip heater to warm the gearbox 200 W
Gearbox type reduction ratio: 100:1
Net weight 640 kg (with barrier fence)
Operation temperatures -25°C to +50°C
Clutch Heavy-duty
Mechanical endurance (MCBF) (with recommended preventive maintenance)
750.000 cycles at a rate of 100 complete
cycles/hrs max with a maximum of 1000
complete cycles per day