Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
    Zurn

    Wilkins FCIS Connected Flood Control System

    The Flood Control Integrated System (FCIS) prevents flooding of a building, caused by the discharge from a catastrophically fouled Reduced Pressure Principal backflow preventer. The pre-wired FCIS package includes: • Reduced Pressure Principle backflow Preventer and Monitor Switch (Model 375MS or Model 975XL2MS) • Electronic Solenoid Time (Model EST) Signal Relay attached to a Solenoid Control Valve (Model ZW206) to shut-off the water supply
    Opis
    • The Flood Control Integrated System(FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375MS, 375AMS, 375ASTMS, or 975XL2MS), a Solenoid Control Valve(SCV) (Model ZW206), and an Electric Solenoid Timer (Model EST) and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor Switch that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The EST shall have an input voltage of 120 VAC, and shall be provided with outputs of 24 VAC and 120 VAC controlled by a user adjusted time delay relay. The EST shall be housed in a water-tight fiberglass NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and EST, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and Electronic Solenoid Timer assembled as a complete unit shall be the Zurn Wilkins FCIS.
    Specyfikacja techniczna
    • Nr referencyjnyzurn-fcis
    • Rodzina produktuBackflow Preventers
    • Grupa produktuReduced Pressure Principle Assembly, Detector
    • TypObiekt (jeden obiekt)
    • Data publikacji2017-01-16
    • Numer edycji3
    • Wysokość (cale)27.25
    • Szerokość (cale)14.25
    • Głębokość (cale)43
    Dodatkowe informacje
    • Materiał głównyDuctile Iron
    • Materiał dodatkowyStal nierdzewna
    • Zaprojektowano wStany Zjednoczone
    • Waga netto (lbs)153
    Klasyfikacja
    • Kategoria BIMobjectHydraulika - Zawory

    Dostępny w krajach:

    Ameryka północna
    Anguilla
    Antigua i Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudy
    Brytyjskie Wyspy Dziewicze
    Curaçao
    Dominika
    Dominikana
    Grenada
    Grenlandia
    Gwadelupa
    Gwatemala
    Haiti
    Holandia Karaibska
    Honduras
    Jamajka
    Kajmany
    Kanada
    Kostaryka
    Kuba
    Martynika
    Meksyk
    Montserrat
    Nikaragua
    Panama
    Portoryko
    Saint Kitts i Nevis
    Saint Lucia
    Saint Martin
    Saint Vincent i Grenadyny
    Salwador
    Sint Maarten
    Stany Zjednoczone
    Trynidad i Tobago
    Turks i Caicos
    Wspólnota Saint-Barthélemy
    Wspólnota Terytorialna Saint Pierre i Miquelon
    Wyspy Dziewicze