Double Check Detector Assemblies - 007M1DCDA
Watts

Double Check Detector Assemblies - 007M1DCDA

The Model 007M1DCDA Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This device assembly is primarily used on commercial fire sprinkler systems where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Maximum Working Pressure: 175psi (12.06 bar).

  • Compact design for easy installation in tight places
  • Can replace seats, seat discs, and auxiliary line and components in the field
  • Auxiliary bypass line detects costly underground water leaks or illegal taps
  • Single cover, top-entry design allows for convenient access for maintenance


Spesifikasjon
  • Keywords: assembly, backflow, backflow preventer valve, backflow valve, bronze body, bypass, cast iron, check valve, cover, dcda, detector, double, double check, doublecheck, epoxy coated, meter, pex crimping tools, pex tools, pressure valve, pressure zone valve, preventer, reduced pressure valve, repairkit, replacement, rpza, shut-off, steam, steamtrap, trap, valve, vlv, watts regulator, plumbing, drains, drainage
Tekniske spesifikasjoner
  • Unik ref.Double-Check-Detector-Assemblies-007M1DCDA
  • ProduktfamiliePlumbing & Flow Control Solutions
  • ProduktgruppeBackflow Preventers > Double Check Detector Assemblies
  • TypeObjekt (enkelt objekt)
  • Utgivelsesdato2019-01-01
  • Utgavenummer1
Relatert
  • HovedmaterialeBronze
  • Designet iUSA
  • Produsert iUSA
Klassifisering
  • BIMobject kategoriRørsystem - Ventiler
  • IFC-klassifiseringVentil
  • UNSPSC-navnValves
  • UNSPSC-kode401416
  • Uniclass 2015 kodePr_65_54_95_05
  • Uniclass 2015 beskrivelseBackflow prevention devices
  • CSI MasterFormat 2014 kode40 05 67.16
  • CSI MasterFormat 2014 tittelDouble Check Valve Assembly Backflow Preventers for Process Service
  • OmniClass-nummer23-27 31 11
  • OmniClass-tittelBackflow Preventors
  • CSI UniFormat II kodeD20
  • CSI UniFormat II tittelPLUMBING

Tilgjengelighet etter region

Nord Amerika
Canada
USA
Common.Footer.ValueProp.Image.AltText

Design App for Revit

Last inn familier direkte i Revit-modellen din med ett klikk

Få et sted for enklere tilgang til nye objekter, lagre Revit-familiene dine og samarbeid med teamet ditt.

  • Huk avArbeid direkte med BIM-objekter ved siden av Revit
  • Huk av 2 GB skylagring – lagre Revit-innholdet ditt
  • Huk av Få LCA for innebygd karbon (A1–A3) direkte fra Revit