STANDARD TECHNICAL CHARACTERISTICS
Electrical supply Single-phase 230 VAC + ground, 50/60 Hz.
(Do not connect to a floating network or to high impedance earthed industrial distribution network)
Three-phase asynchronous 120 W motor.
Nominal consumption 250 W / per gate.
Ambient T° of operation from 0 °C to +50 °C
Relative humidity max. 95% without condensation
Net weight of a cabinet depending on its configuration (left, right, intermediate): between 180 kg and 250 kg.
Min opening or closing times
Opening time: 0.7 s
Closing time: 0.8 s
(Minimum movement times, configurable. These times do not take into account the reaction of the access control system. The passage request memory function makes it possible to accelerate the flow: no closing between 2 requests)
MCBF (Average number of cycles between breakdowns), when respecting recommended maintenance: 5.000.000.
IP40
CAN bus communication between the various modules making up the passage.
Conforms to CE standards. The silicon protection strip on mobile leaf option is necessary to comply with the norms related to impact force.