Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels
Sound Silencer™ - Ceiling and Wall Acoustical Panels

    Sound Silencer™ - Ceiling and Wall Acoustical Panels

    Sound Silencer™ Acoustical Panels
    Durable. Cleanable. Beautiful.

    Designed for the most challenging and unique acoustic environments, Sound Silencer™ ceiling and wall panels provide high-performance sound control with a clean, modern finish. Made from rigid, porous ARPRO Acoustical Porous Expanded Polypropylene (P.E.P.P.), these lightweight panels deliver both sound absorption (NRC) and sound blocking (STC) — offering an effective, versatile solution for noise reduction across a variety of interior settings.

    With a Class A fire rating (ASTM E84) and a non-fibrous, impact-resistant surface, Sound Silencer™ panels are ideal for projects where durability, hygiene, and acoustical performance are critical — including gymnasiums, natatoriums, clean rooms, laboratories, food prep areas, firing ranges, and high-moisture environments.

    Key Advantages:

    • Dual-performance: NRC and STC rated
    • Class A fire rated for code compliance
    • Fiberglass-free and non-irritating to indoor air quality
    • Water-resistant and easily cleanable
    • Tackable and non-abrasive surface
    • Suitable for indoor and outdoor installations
    • Resistant to moisture, bacteria, fungi, and physical impact
    • Lightweight for fast installation and cost-efficient shipping

    Whether you're specifying acoustical materials for a wellness center, educational facility, or industrial environment, Sound Silencer™ panels provide a seamless balance of performance, resilience, and design flexibility.

    Spesifikasjon
    • SECTION 09 84 33

      Sound SilencerTM Acoustic Wall Panels

      PART 1 GENERAL

      1. SECTION INCLUDES
        1. Sound SilencerTM acoustic wall panels and accessories for wall installation.
      2. REFERENCES
        1. American Society for Testing and Materials (ASTM)
          1. ASTM E84: Standard Test Method for Surface Burning Characteristics of Building Materials.
          2. ASTM E90: Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
          3. ASTM C423: Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.
          4. ASTM E795: Standard Practices for Mounting Test Specimens During Sound Absorption Tests
        2. International Code Council (ICC)
          1. ICC IBC: International Building Code
      3. SUBMITTALS
        1. Product Data: Manufacturer’s data sheet and installation instructions.
        2. Samples: Submit, at minimum, a 4” x 4” sample for each type of specified acoustical panel.
        3. Test Reports: Upon request, submit certified test reports to verify specified product performance.
      4. QUALITY ASSURANCE
        1. Qualifications:
          1. Manufacturers: Provide acoustical wall panels from a single manufacturer.
          2. Installers: Utilize an installer having demonstrated experience on projects of comparable size and complexity.
        2. Performance Requirements:
          1. Surface Burning Characteristics: Acoustical panels to perform as specified when tested in accordance with ASTM E84. Acoustical panel surface burning performance should comply with the International Building Code and other local building code requirements.
          2. Acoustical Characteristics: Acoustical panels to perform as specified when tested in accordance with ASTM C423, and ASTM E90.
      5. DELIVERY, STORAGE, AND HANDLING
        1. Storage and Handling Requirements:
          1. Handle panels carefully to avoid any damage.
          2. Store panels indoors in a clean, cool, dry place, and out of direct sunlight.
          3. Store panels in a space where the ambient temperature and humidity conditions are being maintained at the levels indicated for the project when occupied for its intended use.
      6. SITE CONDITIONS
        1. Ambient Conditions:
          1. Maintain ambient temperature and humidity conditions at levels indicated for the project when occupied for its intended use.
          2. Do not install products under environmental conditions outside manufacturer’s recommended limits.
        2. Existing Conditions: Do not install wall panels until space is enclosed and weather proofed, and wet work is completely dry.
      7. WARRANTY
        1. Provide manufacturer’s written product warranty per Section 01 77 00 – Closeout Procedures.

      PART 2 PRODUCTS

      (Specifier Note: Red colored text below requires you to select an option before this specification can be completed. Options in red text are bound by parenthesis. Additional information can be found on our website (www.acousticalsurfaces.com)

      1. MANUFACTURERS
        1. Acoustical Surfaces, Inc., 123 Columbia Court N, Chaska, MN 55318.
          Phone: 952-448-5300. Fax: 952-448-2613. Website: www.acousticalsurfaces.com
      2. DESCRIPTION
        1. Product: Sound SilencerTM acoustic wall panels by Acoustical Surfaces, Inc.
        2. Product Options:
          1. Panel Composition: Semi-rigid porous expanded polypropylene acoustical bead foam
          2. Panel Thickness: (1”) / (2”)
          3. Panel Size: (2’ x 2’) / (2’ x 4’) / (Custom Size - cut down from a 2'x4')
          4. Edge Profile: (Square) / (Beveled)
          5. Finish: (Charcoal) / (White)
          6. Mounting Method: (Direct Attachment) / (Adhesive) / (Z-bars)
        3. Product Performance:
          1. Acoustical Performance
            1. Noise Reduction Coefficient (NRC) per ASTM C423
    • Thickness

      1”

      2”

      A Mount

      0.45

      0.70

      C-25 Mount

      0.80

      0.90

      1. Sound Transmission Classification (STC) per ASTM E90

      Thickness

      1”

      2”

      STC

      9

      13

      OITC

      8

      11

      1. Surface Burning Performance
        1. Fire Rating per ASTM E84: Class A.

      PART 3 EXECUTION

      1. EXAMINATION
        1. Verification of Conditions:
          1. Examine surfaces scheduled to received furred out or directly attached acoustical units for unevenness, irregularities or dampness that would affect quality and execution of work.
          2. All wet work in the installation area must be complete, cured, and dry prior to installation.
          3. Wall assembly shall be complete, inspected, and accepted before wall work begins.
      2. INSTALLATION
      3. Comply with manufacturer’s instructions and recommendations for installation of wall panels and with industry standards.
      4. CLEANING
      5. Clean surfaces of wall panels per manufacturer’s instructions or recommendations.
      6. Remove and replace damaged or discolored material and material that cannot be properly cleaned.
      7. PROTECTION
      8. Protect installed work from damage due to subsequent construction activity, including temperature and humidity limitations and dust control, so that the work will be without damage and deterioration at the time of acceptance by the owner.

      END OF SECTION

      Keywords:
      polypropylene acoustic panels
      washable sound panels
      durable acoustic material
      indoor/outdoor acoustics
      tackable acoustical panels
      water-resistant acoustical panels
      lightweight sound panels
      abuse-resistant acoustical panels
      non-abrasive acoustics
      server room panels
      restaurant acoustical panels
      dual-purpose acoustic panels
      cleanable wall panels
      kennel acoustics
      porous acoustical panels
      Sound Silencer polypropylene acoustic panels
      non-fibrous acoustical wall and ceiling panels
      washable sound absorption panels
      impact-resistant acoustic panels
      Class A fire-rated polypropylene panels
      lightweight acoustic wall panels
      durable soundproofing panels for commercial spaces
      high NRC panels for echo and reverberation control
      moisture-resistant and washable acoustic solution
      odor-resistant polypropylene panels
      safe, non-toxic, non-fibrous acoustical treatment
      ideal for high-humidity and sanitary environments
      dual-purpose sound absorption and tackable surface
      fire-rated for safety compliance
      color options for Sound Silencer panels
      custom sizes and shapes for wall and ceiling panels
      decorative acoustic panels for modern interiors
      smooth, cleanable polypropylene finish
      architectural acoustic design elements
      modular panel systems for flexible layouts
      acoustic panels for server rooms and data centers
      sound absorption panels for restaurants and hospitality spaces
      noise control for animal hospitals and kennels
      acoustic treatment for food prep areas and kitchens
      panels for schools, classrooms, and cafeterias
      industrial and commercial spaces with high noise levels
      easy-to-install wall and ceiling panels
      lightweight panels for quick mounting
      washable and low-maintenance acoustic solution
      safe for high-traffic and sanitary environments
      fire-rated polypropylene finish for code compliance
      moisture-resistant wall panels for food prep areas
      odor-resistant acoustic panels for restaurants and kitchens
      cleanable non-fibrous acoustic panels for sanitary spaces
      affordable polypropylene acoustic panels for large rooms
      modular wall and ceiling panel systems for echo reduction
      custom-size Sound Silencer panels for architectural design

    Tekniske spesifikasjoner
    • Unik ref.nst14686
    • ProduktfamilieWalls
    • ProduktgruppeCeiling and Wall Panels
    • TypeByggemateriale
    • Utgivelsesdato2013-08-07
    • Utgavenummer1
    • Høyde (tommer)48
    • Bredde (tommer)24
    Relatert
    • Hovedmaterialeutvidet polypropylen
    Klassifisering
    • BIMobject kategoriByggematerialer - Akustiske Plater og tilbehør
    • IFC-klassifiseringVegg
    • Uniclass 2015 kodeSs_25_25_05
    • Uniclass 2015 beskrivelseAcoustic panel systems
    • CSI MasterFormat 2014 kode09 80 00
    • CSI MasterFormat 2014 tittelAcoustic Treatment
    • OmniClass-nummer23-15 15 29
    • OmniClass-tittelAcoustical Wall Finishes

    Tilgjengelighet etter region

    Nord Amerika
    Anguilla
    Antigua og Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Canada
    Cayman Islands
    Costa Rica
    Cuba
    Curaçao
    Den dominikanske republikk
    Dominica
    El Salvador
    Grenada
    Grønland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Jomfruøyene
    Jomfruøyene
    Karibisk Nederland
    Martinique
    Mexico
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts og Nevis
    Saint Lucia
    Saint Pierre og Miquelon
    Saint Vincent og Grenadinene
    Saint-Barthélemy
    Saint-Martin
    Sint Maarten
    Trinidad og Tobago
    Turks- og Caicosøyene
    USA
    Common.Footer.ValueProp.Image.AltText

    Design App for Revit

    Last inn familier direkte i Revit-modellen din med ett klikk

    Få et sted for enklere tilgang til nye objekter, lagre Revit-familiene dine og samarbeid med teamet ditt.

    • Huk avArbeid direkte med BIM-objekter ved siden av Revit
    • Huk av 2 GB skylagring – lagre Revit-innholdet ditt
    • Huk av Få LCA for innebygd karbon (A1–A3) direkte fra Revit