Publiceer je producten
Wilkins 975XL2 Reduced Pressure Principle Backflow Preventer, 1/4" to 1/2", Lead-Free*
Zurn

Wilkins 975XL2 Reduced Pressure Principle Backflow Preventer, 1/4" to 1/2", Lead-Free*

4.6 out of 5 stars4.6(12 reviews)

The Reduced Pressure Principle Backflow Preventer shall be certified to NSF/ANSI/CAN 61 and 372, shall be ASSE® Listed 1013, rated to 180° F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The checks shall be oriented at a 45° angle upward and accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap and “Y” type strainer. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL2.

Compliance:

  • NSF61
  • NSF 372
  • ASSE 1013
  • AWWA C511
  • CSA B64.4
  • cUPC
  • IPC
  • NPCC

Features:

  • Top access checks provide easy access for repairs in compact locations
  • Short lay length eases replacement and installation costs
  • Check and relief valve seats are easily replaceable
  • All cast bronze body and stainless steel internals provide corrosion-resistance
  • Low-lead law compliant

Keywords: Backflow Preventer, hazard protection, Reduced Pressure Principle, Zurn Wilkins 975XL2, Reduced Pressure Principle Backflow Preventer, Reduced Pressure Backflow Preventer, relief valve, check valve, reduced pressure principle backflow prevention assembly, reduced pressure zone backflow preventer, backflow relief valve, backflow pressure relief valve, zurn 975xl2, wilkins zurn 975xl2

Specificatie
  • The Reduced Pressure Principle Backflow Preventer shall be certified to NSF/ANSI 61 shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL2.

Technische specificatie
  • Unieke ref.zurn-975xl2
  • ProductfamilieBackflow Preventers
  • ProductgroepReduced Pressure Principle Assembly
  • TypeObject (enkelvoudig object)
  • Publicatiedatum2017-01-16
  • Editienummer2
  • Hoogte (inch)6
  • Breedte (inch)4.25
  • Diepte (inch)9.5
Gerelateerd
  • HoofdmateriaalBronze
  • Ontworpen inVerenigde Staten
  • Nettogewicht (lbs)7
Classificatie
  • Categorie BIMobjectLoodgieterswerk - Kleppen
  • IFC-classificatieKlep
  • Uniclass 2015-codePr_65_54_94_72
  • Uniclass 2015-beschrijvingReduced pressure zone valves
  • CSI MasterFormat 2014 Code40 05 67
  • CSI MasterFormat 2014 TitelSpecialized Pressure and Flow-Control Valves
  • OmniClass-nummer23-27 31 47
  • OmniClass-titelPressure Regulating Valves

Beschikbaarheid regio

Noord Amerika
Amerikaanse Maagdeneilanden
Anguilla
Antigua en Barbuda
Aruba
Bahama's
Barbados
Belize
Bermuda
Britse Maagdeneilanden
Canada
Caribisch Nederland
Costa Rica
Cuba
Curaçao
Dominica
Dominicaanse Republiek
El Salvador
Grenada
Groenland
Guadeloupe
Guatemala
Haïti
Honduras
Jamaica
Kaaimaneilanden
Martinique
Mexico
Montserrat
Nicaragua
Panama
Porto Rico
Saint Kitts en Nevis
Saint Martin
Saint Vincent en de Grenadines
Saint-Barthélemy
Saint-Pierre en Miquelon
SaintLucia
Sint Maarten
Trinidad en Tobago
Turks- en Caicoseilanden
Verenigde Staten