    Wilkins 950XLT2 Double Check Backflow Preventer

    The Double Check Type Backflow Preventer shall be certified to NSF/ANSI 61, shall be ASSE Listed 1015, rated to 180° F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be NORYL™ and the seat disc elastomers shall be SILICONE. The first and second check shall be located at a 45° angle and accessible for maintenance from the top of the device, without removing the device from the line. Each check shall have separate access covers and test cocks shall be accessible from the top of the device. Test cocks shall be protected from debris by a plug. The Double Check Type Backflow Preventer shall be a ZURN WILKINS Model 950XLT2.

    Compliance:

    • ASSE® Listed 1015
    • cUPC® Listed
    • CSA® Certified B64.5
    • AWWA Compliant C510
    • USC Approved
    • NSF/ANSI/CAN 61 & 372

    Features:

    • Sizes: 3/4", 1", 1 1/4", 1 1/2", 2"
    • Maximum working water pressure 175 PSI
    • Maximum working water temperature 180°F
    • Hydrostatic test pressure 350 PSI
    • End connections Threaded ANSI B1.20.1

    Keywords: Double Check Backflow Preventer, double check backflow preventer zurn wilkins, wilkins backflow preventer, double check backflow preventer zurn installation, ,zurn backflow preventer parts

    Voce di capitolato
    • Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. A test cock plug is provided to protect against fouling caused by insects, dirt and debris. Assembly shall provide protection where a potential non-health hazard exists.

    Specifiche tecniche
    • Rif. Unicozurn-950xlt2
    • Famiglia di prodottoBackflow Preventers
    • Gruppo di famigliaDouble Check Assembly
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2017-01-16
    • Numero di versione1
    Relativo a
    • Materiale principaleBronzo
    • Materiale secondarioBronzo
    • Progettato inStati Uniti
    Classificazioni
    • Categoria BIMobjectImpianto idraulico - Valvole

    Disponibilità Regionale

    Nord America
    Anguilla
    Antigua e Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Canada
    Costa Rica
    Cuba
    Curaçao
    Dominica
    El Salvador
    Giamaica
    Grenada
    Groenlandia
    Guadalupa
    Guatemala
    Haiti
    Honduras
    Isole BES
    Isole Cayman
    Isole Turks e Caicos
    Isole Vergini Americane
    Isole Vergini britanniche
    Martinica
    Messico
    Montserrat
    Nicaragua
    Panamá
    Porto Rico
    Repubblica Dominicana
    Saint Kitts e Nevis
    Saint Martin
    Saint Vincent e Grenadine
    Saint-Barthélemy
    Saint-Pierre e Miquelon
    Santa Lucia
    Sint Maarten
    Stati Uniti
    Trinidad e Tobago