AAV-TEE Redi Vent Air Admittance Valve with Tubular Adaptor

AAV-TEE Redi Vent Air Admittance Valve with Tubular Adaptor

An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent and island fixture vent that is provided to prevent siphonage of a fixture trap.  An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere.

Location:

  • The air admittance valve shall be located a minimum of 4” above the horizontal branch drain or fixture drain being vented.
  • Each valve should be installed in an accessible location.

Installation:

  • The valve should be connected to the piping in accordance with the manufacturer’s installation instructions.
  • The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system.
  • A minimum of one vent shall extend to the open atmosphere for ever building drainage system.
  • The valve should not be installed as a vent terminal for any special (chemical) waste system or in supply and return air plenums.
  • For installation in areas with temperature range between –40 and 150 degrees F.

Features:

  • Screening on the inside and outside of the valve to protect the sealing assembly from insects and debris.
  • Will vent up to 20 DFUs on a horizontal branch and 24 DFUs on a stack.
  • Limited lifetime warranty for replacement of defective valves.

Materials:

  • ABS (acrylonitrile butadiene styrene) valve with silicone membrane
  • ABS or PVC (adaptor)

Performance Standards: ANSI/ASSE 1051—2009 single fixture and branch type AAVs ANSI/ASSE 1050—2009 stack type AAVs NSF Standard 14—2009 Plastics Piping System and Components

Code Compliance:

  • International Plumbing Code (IPC)
  • International Residential Code (IRC)
  • Uniform Plumbing Code (UPC Section 301.2 Alternative Materials and Methods
  • National Standard Plumbing Code (NSPC)—Appendix “E”
  • National Plumbing Code of Canada (NPC)
Specifiche tecniche
  • Rif. Unicoips-20391
  • Famiglia di prodottoGeneral Pipework and Ductwork Products
  • Gruppo di famigliaStudor®
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2018-08-31
  • Numero di versione1
Relativo a
  • Materiale principalePVC
  • Progettato inStati Uniti
  • Prodotto inStati Uniti
Classificazioni
  • Categoria BIMobjectImpianto idraulico - Tubature
  • Codice Uniclass 2015Ss_40_15_75_75
  • Descrizione Uniclass 2015Sanitary accessory systems
  • Codice CSI MasterFormat 201422 13 16
  • Titolo CSI MasterFormat 2014Sanitary Waste and Vent Piping
  • Numero OmniClass23-31 00 00
  • Titolo OmniClassPlumbing Specific Products and Equipment
  • Codice CSI UniFormat IID2090
  • Titolo CSI UniFormat IIOther Plumbing Systems

Disponibilità Regionale

Oceania Nord America
Australia
Canada
Nuova Zelanda
Messico
Porto Rico
Stati Uniti
Common.Footer.ValueProp.Image.AltText

App di progettazione per Revit

Carica le famiglie direttamente nel tuo modello Revit con un solo clic

Ottieni un posto per accedere più facilmente a nuovi oggetti, archivia le tue famiglie Revit e collabora con il tuo team.

  • Segno di spuntaLavora direttamente con gli oggetti BIM accanto a Revit
  • Segno di spunta 2 GB di spazio di archiviazione cloud: archivia i tuoi contenuti Revit
  • Segno di spunta Ottieni l'LCA (A1-A3) del carbonio incorporato direttamente da Revit