Overview:

The Auxiliary Power Supply (APS) is a UL 864, 10th-Edition-listed power supply. It is a 24-Vdc filtered-regulated and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification/ Emergency Communication (MNEC), as well as life safety applications. 

The APS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 24 ampere-hour batteries. The APS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the APS’s unique dual-input circuits. The APS has a door-mounted AC power indicator LED. 

The APS also has room for and can power a number of different modules. These can be Signature AA-30 or AA-50 dual-channel audio amplifiers, SIGA-UIO modules and/or SIGA-RELs. An MN-BRKT3F can also be installed. This bracket can accommodate an MN-FNS4C2F3 or MN-FNS8C2F3 Ethernet network switch, an MN-FVPN VoIP module and an MN-COM1S Communications module. 

The APS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit’s rating. Features:

  • Allows for reliable filtered and regulated power to be installed where needed
  • Cost-effective system expansion
  • Provides for Genesis and Enhanced Integrity notification appliance synchronization
  • Supports coded output operation
  • Self-restoring overcurrent protection
  • Multiple signal rates
  • Can be cascaded or controlled independently
  • Easy field configuration
  • On-board diagnostic LEDs identify wiring or internal faults
  • Standard EDWARDS keyed lockable steel cabinet with removable door
  • 110 and 230 Vac models available
  • Accommodates 18 to 12 AWG wire size
  • Optional tamper switch
  • Dual-battery charging rates
  • Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5

The APS meets current UL requirements and is listed under the following standards:

  • Standard (CCN) Description
  • UL864 10th-Edition (UOXX) Fire Alarm Systems
  • UL636 (ANET, UEHX7) Holdup Alarm Units and Systems
  • UL609 (AOTX, AOTX7) Local Burglar Alarm Units and Systems
  • UL365 (APAW, APAW7) Police Station Connected Burglar Alarm Units and Systems
  • UL1076 (APOU, APOU7) Proprietary Burglar Alarm System Units
  • UL1610 (AMCX) Central Station Alarm Unit
  • ULC-S527 (UOXXC) Control Units, Fire Alarm (Canada)
  • ULC-S303 (AOTX7) Local Burglar Alarm Units and Systems (Canada)
  • C22.2 No. 205 Signaling Equipment (Canada)
Specifikáció
  • Engineering Specification:

    Supply, where needed, EDWARDS APS Series Auxiliary Power Supplies (APS) that are interconnected to and supervised by the main system. The APS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery complement. The APS battery complement shall be sized to match the requirements of the main system. The APS shall be capable of supervising and charging batteries having the capacity of 65 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications. 

    <>The APS shall provide a minimum of four independent, fully supervised Class B circuits that can be field-configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. APS NACs shall be convertible to a minimum of two Class A NACs. Each APS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be provided with automatically restoring overcurrent protection. The APS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. APS NACs shall be configurable for continuous, 3-3-3 temporal rate. Fault conditions on the APS shall not impede operation of main system NAC. The APS shall be provided with ground fault detection circuitry and a separate AC fail relay.

Műszaki specifikáció
  • Egyedi azonosítóedwards-utc-020
  • TermékcsaládElectronics
  • TermékcsoportFire Detection, Monitoring and Alarm
  • TípusObjektum (egy termék)
  • Megjelenés dátuma2018-01-07
  • Verziószám1
Kapcsolódó adatok
  • Elsődleges anyagFém
  • Tervezés helyeEgyesült Államok
  • Gyártás helyeKína
Besorolások
  • BIMobject kategóriaTűzvédelmi termékek - Tűzvédelem
  • IFC besorolásRiasztó
  • ETIM-kódEC002685
  • ETIM-névCentral fire alarm system
  • UNSPSC névAlarm systems
  • UNSPSC kód46171604
  • Uniclass 2015 kódPr_75_75_30_29
  • Uniclass 2015 leírásFire alarm panels
  • CSI MasterFormat 2014 kód28 31 63
  • CSI MasterFormat 2014 névFire Alarm Integrated Audio Visual Evacuation Systems
  • OmniClass szám23-29 31 13
  • OmniClass névFire Alarm Control Panels
  • CSI UniFormat II kódD40
  • CSI Uniformat II névFIRE PROTECTION

Termék elérhetősége

Észak-Amerika
Egyesült Államok
Common.Footer.ValueProp.Image.AltText

Design App a Revithez

Töltse be a családokat közvetlenül a Revit modelljébe egyetlen kattintással

Szerezzen egy helyet, ahol könnyebben hozzáférhet az új objektumokhoz, tárolhatja a Revit családokat és együttműködhet csapatával.

  • PipaDolgozzon közvetlenül a BIM objektumokkal a Revit mellett
  • Pipa 2 GB felhőtárhely – tárolja Revit tartalmát
  • Pipa Szerezzen be megtestesült szén-dioxid LCA-t (A1-A3) közvetlenül a Revitből