Termékek közzététele
PC-100 - Power Conditioner 100
PC-100 - Power Conditioner 100
PC-100 - Power Conditioner 100

    PC-100 - Power Conditioner 100

    The PC-100 is a professional grade, rack-mountable power conditioner designed to provide 120 Volt AC power distribution, switching, surge protection, and noise filtering for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected and filtered. The switched outlets are arranged in four banks of two, two of which are turn-on delayed to prevent dangerous transients during power-up.

    Power Conditioning
    A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-100 includes the following power conditioning features:
    • Surge Protection — Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances
    • Under/Over Voltage Cutoff — Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range
    • Thermal Breaker — Disrupts power to all outlets in case of an overload condition
    • EMI/RFI Noise Filtering — Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality
    • Wiring Fault Detection — Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [1]
    Three-Stage Sequential Turn-On Delay
    The switched outlets on the PC-100’s rear panel are arranged in four banks, with two outlets per bank. When the front panel switch is turned on, or when power is applied to the main line input following a power outage or through an externally switched circuit, the first two banks of outlets turn on immediately, the third bank turns on following a one second delay, and the fourth bank turns on following a two second delay. This ensures that the connected equipment gets powered up in proper order, preventing dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up.


    Protection Status Output

    A contact closure output is included to provide notification to a control system or other equipment if the internal surge protection circuit is compromised due to an extreme transient voltage surge. In the unlikely event of such a condition, the PROTECTION output presents a low-voltage contact closure signal and all power to the rear panel outlets is switched off. Protection status is also indicated via LEDs on the front panel.


    UL® 1449 Certified

    The PC-100 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).

      

    Key Features

    • Rack-mountable power conditioner
    • Eight switched rear panel outlets
    • Three-stage sequential turn-on delay
    • One unswitched front panel outlet
    • Professional grade surge protection
    • UL® 1449 Type 3 Listed
    • Thermal breaker overload protection
    • Over-voltage and under-voltage cutoff
    • EMI and RFI noise filtering
    • Wiring fault detection [1]
    • Front panel main power switch and status indicators
    • Protection status contact closure output
    • Single-space 19 inch rack-mountable
    • Rated 15 Amps at 120 Volts AC
    • Limited Lifetime Product Warranty
    • Limited 5 Year Connected Equipment Protection Warranty

    1. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-100 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-100 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.

    Specifikáció
    • Power Conditioner
      Maximum Output Current, Total - 15 Amps @ 120 Volts AC
      Maximum Output Current, Per Outlet/Bank - 15 Amps @ 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined)
      Filtration - 40 dB @ 100 kHz, 50 dB @ 300 kHz, with 50 Ohm load
      Surge Protection Modes - L-G, L-N, N-G
      Surge Protection Shutoff - Shuts off rear outlets if surge protection is compromised
      Energy Dissipation - 2000 Joules per Mode
      Clamping Voltage - 370 Volts
      Clamping Time - 1 ns
      Wiring Fault Detection - Shuts off rear outlets if a wiring fault is detected at the input [1]
      Under-Voltage Cutoff - Shuts off rear outlets if input drops below 93 Volts
      Over-Voltage Cutoff - Shuts off rear outlets if input exceeds 135 Volts
      Turn-On Delay - SWITCHED ON 1: 0 seconds; SWITCHED ON 2: 0 seconds;  DELAYED ON 1: 1 second; DELAYED ON 2: 2 seconds

      Power
      Line Power - 15 Amps @ 120 Volts AC, 60 Hz
      Power Consumption - ~10 Watts typical, 30 Watts maximum (not including load)

      Connectors
      120V~ 15A 60Hz - (1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug; Line power input
      SWITCHED ON 1 - (2) NEMA 5-15R AC power outlets; Switched 120 Volt AC power outlet bank; Turn-On Delay: 0 seconds
      SWITCHED ON 2 - (2) NEMA 5-15R AC power outlets; Switched 120 Volt AC power outlet bank; Turn-On Delay: 0 seconds
      DELAYED ON 1 - (2) NEMA 5-15R AC power outlets; Switched 120 Volt AC power outlet bank; Turn-On Delay: 1 second
      DELAYED ON 2 - (2) NEMA 5-15R AC power outlets; Switched 120 Volt AC power outlet bank; Turn-On Delay: 2 seconds
      PROTECTION - (1) 2-pin 3.5 mm detachable terminal block; Normally open, isolated relay; Rated 1 Amp, 30 Volts AC/DC; Provides a dry contact closure if surge protection is compromised
      G - (1) 6-32 screw, chassis ground lug
      ALWAYS ON (front) - (1) NEMA 5-15R AC power outlet; Unswitched 120 Volt AC power outlet 

      Controls & Indicators
      PWR - (1) Bi-color green/amber LED, indicates line power is present and the power switch is on (green) or off (amber)
      FAULT - (1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [1]
      PROTECT - (1) Green LED, indicates surge protection is fully functional
      SHUTDOWN - (1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, line input miswire, missing ground, or compromised surge protection fault condition
      Power Switch - (1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately
      THERMAL BREAKER (rear) - Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved

      Environmental
      Temperature - 32° to 113° F (0° to 45° C)
      Humidity - 10% to 90% RH (non-condensing)
      Heat Dissipation - 34 BTU/hr typical; 102 BTU/hr maximum

      Construction
      Chassis - Steel, black finish
      Front Panel - Extruded aluminum, black finish, polycarbonate label overlay
      Mounting - 1 RU 19-inch rack-mountable (rack ears included)

      Dimensions
      Height - 1.73 in (44 mm) without feet
      Width - 17.32 in (440 mm); 19.00 in (483 mm) with rack ears
      Depth - 10.56 in (269 mm)
      Weight - 8.2 lb (3.8 kg)

      Compliance
      UL 1449 Type 3 Listed

      1. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-100 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-100 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.

    Műszaki specifikáció
    • Egyedi azonosítócrestron-PC-100
    • TermékcsaládAccessories
    • TermékcsoportPower Supplies
    • TípusObjektum (egy termék)
    • Megjelenés dátuma2018-04-30
    • Verziószám1
    • Magasság (hüvelyk)1.73
    • Mélység (hüvelyk)10.56
    Kapcsolódó adatok
    • Tervezés helyeEgyesült Államok
    • Gyártás helyeEgyesült Államok
    • Nettó tömeg (font)3.8
    Besorolások
    • BIMobject kategóriaElektronika - Controls
    • IFC besorolásElektromos készülék
    • ETIM-kódEC000678
    • ETIM-névRemote control
    • UNSPSC névElectrical controls and accessories
    • UNSPSC kód391215
    • Uniclass 2015 kódPr_40_30_86_88
    • Uniclass 2015 leírásTouch panels
    • CSI MasterFormat 2014 kód40 67 23
    • CSI MasterFormat 2014 névControl System Consoles
    • OmniClass szám23-27 13 13 11
    • OmniClass névBuilding Automated Control Panels

    Termék elérhetősége

    Európa Ázsia Észak-Amerika Afrika Dél-Amerika Óceánia
    Åland
    Afganisztán
    Anguilla
    Algéria
    Argentína
    Amerikai Szamoa
    Albania
    Azerbajdzsán
    Antigua és Barbuda
    Angola
    Bolívia
    Ausztrália
    Andorra
    Bahrein
    Aruba
    Benin
    Brazília
    Cook-szigetek
    Ausztria
    Banglades
    Bahama-szigetek
    Bissau-Guinea
    Chile
    Észak-Mariana-szigetek
    Belgium
    Bhután
    Barbados
    Botswana
    Ecuador
    Fidzsi-szigetek
    Bosznia-Hercegovina
    Brit Indiai-óceáni Terület
    Belize
    Burkina Faso
    Falkland-szigetek
    Francia Polinézia
    Bulgária
    Brunei Szultanátus
    Bermuda
    Burundi
    Francia Guyana
    Guam
    Ciprus
    Christmas Island
    Brit Virgin-szigetek
    Comore-szigetek
    Guyana
    Kelet-Timor
    Csehország
    Dél-Korea
    Caribbean Netherlands
    Csád
    Kolumbia
    Kiribati
    Dánia
    Egyesült Arab Emírségek
    Costa Rica
    Dél-afrikai Köztársaság
    Paraguay
    Marshall-szigetek
    Egyesült Királyság
    Észak-Korea
    Curaçao
    Dél-Szudán
    Peru
    Mikronéziai Szövetségi Államok
    Észak-Macedónia
    Fülöp-szigetek
    Dominikai Közösség
    Dzsibuti
    Suriname
    Nauru
    Észtország
    Grúzia
    Dominikai Köztársaság
    Egyenlítői-Guinea
    Uruguay
    Niue
    Fehéroroszország
    Hongkong
    Egyesült Államok
    Egyiptom
    Venezuela
    Norfolk-sziget
    Feröer-szigetek
    India
    El Salvador
    Elefántcsontpart
    Palau
    Finnország
    Indonézia
    Grenada
    Eritrea
    Pápua Új-Guinea
    Franciaország
    Irak
    Grönland
    Etiópia
    Pitcairn-szigetek
    Gibraltár
    Irán
    Guadeloupe
    Gabon
    Salamon-szigetek
    Görögország
    Izrael
    Guatemala
    Gambia
    Szamoa
    Guernsey
    Japán
    Haiti
    Ghána
    Tokelau
    Hollandia
    Jemen
    Honduras
    Guinea
    Tonga
    Horvátország
    Jordánia
    Jamaica
    Kamerun
    Tuvalu
    Írország
    Kambodzsa
    Kajmán-szigetek
    Kenya
    Új-Kaledónia
    Izland
    Katar
    Kanada
    Kongó
    Új-Zéland
    Jersey
    Kazahsztán
    Kuba
    Kongói Demokratikus Köztársaság
    United States Minor Outlying Islands
    Lengyelország
    Kína
    Martinique
    Közép-afrikai Köztársaság
    Vanuatu
    Lettország
    Kirgizisztán
    Mexikó
    Lesotho
    Wallis és Futuna
    Liechtenstein
    Kókusz-szigetek
    Montserrat
    Libéria
    Litvánia
    Kuvait
    Nicaragua
    Líbia
    Luxemburg
    Laosz
    Panamaváros
    Madagaszkár
    Magyarország
    Libanon
    Puerto Rico
    Malawi
    Málta
    Makaó
    Saint Kitts és Nevis
    Mali
    Man-sziget
    Malajzia
    Saint Lucia
    Marokkó
    Moldova
    Maldív-szigetek
    Saint Pierre és Miquelon
    Mauritánia
    Monaco
    Mianmar (Burma)
    Saint Vincent és a Grenadine-szigetek
    Mauritius
    Montenegró
    Mongólia
    Saint-Barthélemy
    Mayotte
    Németország
    Nepál
    Saint-Martin
    Mozambik
    Norvégia
    Omán
    Sint Maarten
    Namíbia
    Olaszország
    Örményország
    Trinidad és Tobago
    Niger
    Oroszország
    Pakisztán
    Turks- és Caicos-szigetek
    Nigéria
    Portugália
    Palesztina
    Virgin-szigetek
    Nyugat-Szahara
    Románia
    Srí Lanka
    Réunion
    San Marino
    Szaúd-Arábia
    Ruanda
    Spanyolország
    Szingapúr
    São Tomé és Príncipe
    Svájc
    Szíria
    Seychelle-szigetek
    Svalbard and Jan Mayen
    Tádzsikisztán
    Sierra Leone
    Svédország
    Tajvan
    Szenegál
    Szerbia
    Thaiföld
    Szent Ilona
    Szlovákia
    Törökország
    Szomália
    Szlovénia
    Türkmenisztán
    Szudán
    Ukrajna
    Üzbegisztán
    Szváziföld
    Vatikán
    Vietnam
    Tanzánia
    Togo
    Tunézia
    Uganda
    Zambia
    Zimbabwe
    Zöld-foki Köztársaság
    Common.Footer.ValueProp.Image.AltText

    Design App a Revithez

    Töltse be a családokat közvetlenül a Revit modelljébe egyetlen kattintással

    Szerezzen egy helyet, ahol könnyebben hozzáférhet az új objektumokhoz, tárolhatja a Revit családokat és együttműködhet csapatával.

    • PipaDolgozzon közvetlenül a BIM objektumokkal a Revit mellett
    • Pipa 2 GB felhőtárhely – tárolja Revit tartalmát
    • Pipa Szerezzen be megtestesült szén-dioxid LCA-t (A1-A3) közvetlenül a Revitből