myRoom XC Guestroom Wireless Processor
myRoom XC Guestroom Wireless Processor

    myRoom XC Guestroom Wireless Processor

    Traduit par Google,
    Le processeur sans fil de la chambre d'hôtel intègre les appareils Clear Connect – Type X (tels que les charges Ketra) avec les appareils Clear Connect – Type A (tels que les commandes sans fil Pico et les capteurs Radio Powr Savr).

    Contactez Lutron Electronics

    Spécification
    • Each guestroom wireless processor can communicate with the following: 

      • Clear Connect - Type X devices (100 maximum)– Commercial Ketra Type X loads– Sunnata dimmers / switches / keypads– Lumaris RGB + Tunable White tape light – Athena wireless nodes– Rania D2 

      • Clear Connect - Type A devices (50 maximum)– Pico wireless controls– Radio Powr Savr occupancy/vacancy sensors (15 maximum) Features 

      • Powered by an IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ power supply, Lutron model L-POEI-BL or by others (sold separately). 

      • Timeclock scheduling of daily events. 

      • Connects to the network via an Ethernet connection. 

      • Local device operation will continue to function if internet connection is lost.

      Specifications 

      Regulatory Approvals • cULus • FCC • IC • NOM • IFTEL 

      PoE Power • Processor is an IEEE 802.3af compliant Class 1 device; typical 1.5 W (max 4.0 W) • 48 V- 100 mA (IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+) • Compatible power supply: L-POEI-BL available for purchase separately, or IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ supply by others 

      Environment • Operating temperatures 32 °F to 104 °F (0 °C to 40 °C) • Relative humidity: 0% to 90% non-condensing • For indoor use only 

      ESD Protection • Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. 

      Surge Protection • Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits. 

      Power Failure • 10-year power failure memory: Should the power be interrupted, the wireless processor will return to its previous state prior to the interruption when power is restored.

      Mounting • The guestroom wireless processor can be recess-mounted or wall-mounted using the included recess bracket or junction box bracket in a nonmetal ceiling tile or drywall. When mounting on a 4 in x 4 in (102 mm x 102 mm) junction box, a mud ring (not supplied) must be used. • The guestroom wireless processor can also be shelf-mounted using the L-SMNT-WH (sold separately). • The guestroom wireless processor and Clear Connect - Type X devices must be mounted 5 ft (1.5 m) away from wireless interference sources like microwaves, Wireless Access Points (WAP), etc. • Do not install the guestroom wireless processor in metallic enclosures. • Do not install the guestroom wireless processor above metal ceilings or tiles with metal backing. 

      Wiring • Use Cat5e minimum cable. Maximum length is 328 ft (100 m) from router to processor. Each wireless processor needs to have a home run Ethernet connection back to the PoE supply. • PoE wiring must be kept internal to the building. Do not run PoE wiring outdoors

    Spécifications techniques
    • Réference unique.lutron-myroomxc-rf2-gcu
    • Famille de produitsLighting Controls
    • Groupe de produitsmyRoom XC
    • TypeObjet (objet simple)
    • Date de publication2026-04-17
    • Numéro d'édition1
    • Hauteur (pouces)4.04
    • Largeur (pouces)4.04
    • Profondeur (pouces)1.17
    En rapport
    • Matériel principalPlastique
    Classification
    • BIMobject CatégorieElectrique - Contrôle d'accès
    Common.Footer.ValueProp.Image.AltText

    Application Design pour Revit

    Chargez des familles directement dans votre modèle Revit en un seul clic

    Bénéficiez d'un endroit pour accéder plus facilement à de nouveaux objets, stocker vos familles Revit et collaborer avec votre équipe.

    • CocheTravaillez directement avec des objets BIM à côté de Revit
    • Coche 2 Go de stockage dans le cloud : stockez votre contenu Revit
    • Coche Obtenez une analyse du cycle de vie du carbone incorporé (A1-A3) directement depuis Revit