Julkaise tuotteesi
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
    Wilkins

    Wilkins 950XL3BFSS Double Check Backflow Preventer

    The Double Check Type Backflow Preventer shall be certified to NSF/ANSI/CAN 61, rated to 180°, and supplied with UL/FM approved butterfly valves with supervisory switch. The main body and access covers shall be low lead bronze (ASTMB 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first andsecond check shall be located at an angle and accessible for maintenance from the top of the device, without removing thedevice from the line. The checks shall share a single access cover and the test cocks shall be accessible from the top ofthe device. The Double Check Type Backflow Preventer shall be a WILKINS Model 950XL3BFSS.

    Compliance:

    • NSFStandard61
    • NSFStandard372
    • ASSEStandards
    • UPC
    • UL
    • IPC
    • NPCC
    • USC Confirmed

    Features:

    • Ideal for use where Lead Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential non-health hazard exists. Features slow closing resilient seated UL/FM approved butterfly shutoffs with supervisory switch. For indoor or outdoor use.
    • Sizes 1 1/4", 1 1/2", 2"
    • Minimum working water pressure: 20 PSI
    • Maximum working water pressure: 175 PSI
    • Minimum working water temperature: 33°F
    • Maximum working water temperature: 180°F
    • Hydrostatic test pressure: 350 PSI
    • End connections Threaded: (FNPT) ANSI B1.20.1

    keywords: Double Check Backflow Preventer, Zurn 950XL3BFSS, double check backflow preventer, potable water backflow valve, Zurn bronze backflow assembly,112-950XL3BFSS,114-950XL3BFSS,2-950XL3BFSS

    Tekniset tiedot
    • Yksilöity viite950XL3BFSS
    • TuoteperheBackflow Preventers
    • TuoteryhmäDouble Check Assembly
    • TyyppiObjekti (yksittäinen objekti)
    • Julkaisupäivä2025-10-23
    • Painoksen numero1
    • Korkeus (tuumaa)7.68
    • Leveys (tuumaa)6
    • Syvyys (tuumaa)15.67
    Liittyviä
    • Ensisijainen materiaaliBronze
    • Suunniteltu:Yhdysvallat
    • Nettopaino (paunaa)18
    Luokitus
    • BIMobject-luokkaPutkityöt - Venttiilit

    Alueellinen saatavuus

    Pohjois-Amerikka
    Anguilla
    Antigua ja Barbuda
    Aruba
    Bahamasaaret
    Barbados
    Belize
    Bermuda
    Brittiläiset Neitsytsaaret
    Caribbean Netherlands
    Caymansaaret
    Costa Rica
    Curaçao
    Dominica
    Dominikaaninen tasavalta
    El Salvador
    Grenada
    Grönlanti
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaika
    Kanada
    Kuuba
    Martinique
    Meksiko
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts ja Nevis
    Saint Lucia
    Saint Vincent ja Grenadiinit
    Saint-Barthélemy
    Saint-Martin
    Saint-Pierre ja Miquelon
    Sint Maarten
    Trinidad ja Tobago
    Turks- ja Caicossaaret
    Yhdysvallat
    Yhdysvaltain Neitsytsaaret
    Common.Footer.ValueProp.Image.AltText

    Design App for Revit

    Lataa perheet suoraan Revit-malliisi yhdellä napsautuksella

    Hanki paikka, jossa voit käyttää uusia objekteja helpommin, tallentaa Revit-perheesi ja tehdä yhteistyötä tiimisi kanssa.

    • ValintamerkkiTyöskentele suoraan BIM-objektien kanssa Revitin vieressä
    • Valintamerkki 2 Gt pilvitallennustilaa – tallenna Revit-sisältösi
    • Valintamerkki Hanki sisällysluettelon hiilijalanjälkilaskenta (A1–A3) suoraan Revitistä