Publish your products
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)
Armatherm™ 500 Series Parapet Roof Penetration (US)

    Armatherm™ 500 Series Parapet Roof Penetration (US)

    Armatherm™ 500 - Parapet Roof Penetration

    Reducing heat flow within a building’s thermal envelope reduces energy consumption as well as potential condensation issues. Armatherm™ 500 thermal break material (TIM) significantly reduces energy lost from thermal bridging in building envelope connections.

    Armatherm™ 500 structural thermal break material is a high density, thermoset polyurethane manufactured in several densities.

    Armatherm™ 500 thermal break material can support high loads and has a selection of four grades of material with different compressive strength capabilities.

    The Armatherm™ 500 thermal insulation blocks have very limited creep under load, plus they do not absorb water because of their closed cell structure. Therefore, energy lost via thermal bridging is reduced within building envelope connections. Heat flow, energy consumption and potentially dangerous condensation issues are all minimised as a result.

    The standard thicknesses Armatherm™ 500 is available in are 5mm, 10mm, 12mm, 15mm, 20mm, 25mm, 50mm. Furthermore, the high density, polyurethane material sheets can be layered or customised with ease to achieve the desired U value and thickness specifications. It is extremely dynamic and can be used across the building, wherever features a penetration or transition exit through a building envelope. It can be cut and drilled on site easily, where a thermal bridge occurs, if necessary. Armatherm™500-320 and Armatherm ™500-490 are the most common specifications.

    Not only is Armatherm™500 the ideal solution to prevent thermal bridging in buildings to reduce heat loss, it is also suitable for cold storage facilities to prevent the subgrade from freezing. This is necessary for frozen food storage, Armatherm™500 sits directly under the column base to prevent the transfer of cold temperatures into the ground.

    Parapet Roof Penetration Thermal Bridging Solution

    Roof to wall and parapet locations require structural framing for support which prevents continuous insulation from roof to facade. This creates a thermal bridge which can be prevented by providing an Armatherm™ 500 series structural thermal break under the parapet connecting the facade and roof insulation and improving the effective R value by as much as 30%. A thermal break can also be installed within the envelope at roof penetration points where structural elements are supported. This provides continuous insulation and prevents potential condensation issues.


    Specification
    • Parapet Roof Penetration Thermal Bridging Solution

      Specifications of Armatherm™ 500 Series 500-080 500-150 500-200 500-280
      Compressive Strength (psi) 210 560 1100 2150
      Compressive Modulus (psi) 6155 18130 29000 49300
      Sheer strength (psi) 145 167 257 310
      Thermal Conductivity (BTU in/hr ft 2F) 0.26 0.32 0.39 0.53
      R Value per Inch 3.85 3.1 2.6 1.9
      Operating Temperature (°F) -300 -300 -300 -300


      thermal break, balcony, parapet, column base, shelf angle, curtain wall, insulation pad, structural thermal break, Armatherm, thermal bridging, psi-value, U-value, energy code, envelope detailing

    Technical specification
    • Unique ref.armatherm-500-Parapet-Roof-Penetration-Thermal-Bridging-Solution-US
    • Product familyArmatherm™ 500
    • Product groupStructural Thermal Break
    • TypeBuilding Materials
    • Date of publishing2024-11-25
    • Edition number1
    Related
    • Material mainPolyurethane
    • Designed inUnited States
    • Manufactured inUnited States
    Classification
    • BIMobject CategoryConstruction Materials - Insulation
    • IFC classificationStructural Connection
    • ETIM CodeEC000406
    • ETIM NameThermal insulation
    • UNSPSC nameThermal insulation
    • UNSPSC code301415
    • Uniclass 2015 CodePr_35_90_15_89
    • Uniclass 2015 DescriptionThermal break connection plates
    • CSI MasterFormat 2014 Code07 21 00
    • CSI MasterFormat 2014 TitleThermal Insulation
    • OmniClass Number23-13 25 19
    • OmniClass TitleThermal Insulation 

    Region availability

    North America South America
    Anguilla
    Argentina
    Antigua and Barbuda
    Bolivia
    Aruba
    Brazil
    Barbados
    Chile
    Belize
    Colombia
    Bermuda
    Ecuador
    British Virgin Islands
    Falkland Islands (Islas Malvinas)
    Canada
    French Guiana
    Caribbean Netherlands
    Guyana
    Cayman Islands
    Paraguay
    Collectivity of Saint Martin
    Peru
    Costa Rica
    Suriname
    Cuba
    Uruguay
    Curaçao
    Venezuela
    Dominica
    Dominican Republic
    El Salvador
    Greenland
    Grenada
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Martinique
    Mexico
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts and Nevis
    Saint Lucia
    Saint Pierre and Miquelon
    Saint Vincent and the Grenadines
    Saint-Barthélemy
    Sint Maarten
    The Bahamas
    Trinidad and Tobago
    Turks and Caicos Islands
    U.S. Virgin Islands
    United States