Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
    Wilkins

    Wilkins 950XL3BFSS Double Check Backflow Preventer

    The Double Check Type Backflow Preventer shall be certified to NSF/ANSI/CAN 61, rated to 180°, and supplied with UL/FM approved butterfly valves with supervisory switch. The main body and access covers shall be low lead bronze (ASTMB 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first andsecond check shall be located at an angle and accessible for maintenance from the top of the device, without removing thedevice from the line. The checks shall share a single access cover and the test cocks shall be accessible from the top ofthe device. The Double Check Type Backflow Preventer shall be a WILKINS Model 950XL3BFSS.

    Compliance:

    • NSFStandard61
    • NSFStandard372
    • ASSEStandards
    • UPC
    • UL
    • IPC
    • NPCC
    • USC Confirmed

    Features:

    • Ideal for use where Lead Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential non-health hazard exists. Features slow closing resilient seated UL/FM approved butterfly shutoffs with supervisory switch. For indoor or outdoor use.
    • Sizes 1 1/4", 1 1/2", 2"
    • Minimum working water pressure: 20 PSI
    • Maximum working water pressure: 175 PSI
    • Minimum working water temperature: 33°F
    • Maximum working water temperature: 180°F
    • Hydrostatic test pressure: 350 PSI
    • End connections Threaded: (FNPT) ANSI B1.20.1

    keywords: Double Check Backflow Preventer, Zurn 950XL3BFSS, double check backflow preventer, potable water backflow valve, Zurn bronze backflow assembly,112-950XL3BFSS,114-950XL3BFSS,2-950XL3BFSS

    Teknisk specifikation
    • Unik ref.950XL3BFSS
    • ProduktfamilieBackflow Preventers
    • ProduktgruppeDouble Check Assembly
    • TypeObjekt (enkelt objekt)
    • Udgivelsesdato2025-10-23
    • Udgavenummer1
    • Højde (tommer)7.68
    • Bredde (tommer)6
    • Dybde (tommer)15.67
    Relateret
    • Materiale primærtBronze
    • Designet iUSA
    • Nettovægt (lbs)18
    Klassifikation
    • BIMobject-kategoriVVS - Ventiler

    Tilgængelighed i region

    Nordamerika
    Anguilla
    Antigua og Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Canada
    Caribbean Netherlands
    Caymanøerne
    Costa Rica
    Cuba
    Curaçao
    De britiske jomfruøer
    Dominica
    Dominikanske Republik
    El Salvador
    Grenada
    Grønland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Jomfruøerne
    Martinique
    Mexico
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts og Nevis
    Saint Lucia
    Saint Pierre og Miquelon
    Saint Vincent og Grenadinerne
    Saint-Barthélemy
    Saint-Martin
    Sint Maarten
    Trinidad og Tobago
    Turks- og Caicosøerne
    USA
    Common.Footer.ValueProp.Image.AltText

    Design App til Revit

    Indlæs familier direkte ind i din Revit-model med ét klik

    Få et sted til at få adgang til nye objekter nemmere, opbevar dine Revit-familier og samarbejd med dit team.

    • MarkeringArbejd direkte med BIM-objekter ved siden af Revit
    • Markering 2 GB cloudlager – gem dit Revit-indhold
    • Markering Få integreret CO2-LCA (A1-A3) direkte fra Revit