Publikovat produkty
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
    Wilkins

    Wilkins FCIS Connected Flood Control System

    The Flood Control Integrated System (FCIS) prevents flooding of a building, caused by the discharge from a catastrophically fouled Reduced Pressure Principal backflow preventer. The pre-wired FCIS package includes: • Reduced Pressure Principle backflow Preventer and Monitor Switch (Model 375MS or Model 975XL2MS) • Electronic Solenoid Time (Model EST) Signal Relay attached to a Solenoid Control Valve (Model ZW206) to shut-off the water supply
    Specifikace
    • The Flood Control Integrated System(FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375MS, 375AMS, 375ASTMS, or 975XL2MS), a Solenoid Control Valve(SCV) (Model ZW206), and an Electric Solenoid Timer (Model EST) and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor Switch that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The EST shall have an input voltage of 120 VAC, and shall be provided with outputs of 24 VAC and 120 VAC controlled by a user adjusted time delay relay. The EST shall be housed in a water-tight fiberglass NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and EST, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and Electronic Solenoid Timer assembled as a complete unit shall be the Zurn Wilkins FCIS.
    Technická specifikace
    • Jedinečná ref. hodnotazurn-fcis
    • Skupina výrobkůBackflow Preventers
    • Skupina produktůReduced Pressure Principle Assembly, Detector
    • TypObjekt
    • Datum zveřejnění2025-09-02
    • Číslo vydání1
    • Výška (palce)27.25
    • Šířka (palce)14.25
    • Hloubka (palce)43
    Související
    • Hlavní materiálDuctile Iron
    • Vedlejší materiálNerezová ocel
    • Navrženo vSpojené státy americké
    • Čistá hmotnost (lb)153
    Klasifikace
    • Kategorie objektu BIMInstalace - Ventily

    Dostupnost regionu

    Severní Amerika
    Anguilla
    Antigua a Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudské ostrovy
    Britské Panenské ostrovy
    Curaçao
    Dominika
    Dominikánská republika
    Gaudeloupe
    Grenada
    Grónsko
    Guatemala
    Haiti
    Honduras
    Jamajka
    Kajmanské ostrovy
    Kanada
    Karibské Nizozemsko
    Kostarika
    Kuba
    Martinik
    Mexiko
    Montserrat
    Nikaragua
    ostrovy Turks a Caicos
    Panama
    Pannenske Ostrovy
    Portoriko
    Saint-Pierre a Miquelon
    Salvador
    Spojené státy americké
    Svatá Lucie
    Svatý Bartoloměj
    Svatý Kryštof a Nevis
    Svatý Martin
    Svatý Martin
    Svatý Vincenc a Grenadiny
    Trinidad a Tobago
    Common.Footer.ValueProp.Image.AltText

    Design App pro Revit

    Načtěte rodiny přímo do svého modelu Revit jedním kliknutím

    Získejte místo pro snadnější přístup k novým objektům, ukládejte své rodiny Revit a spolupracujte se svým týmem.

    • ZaškrtnutíPracujte přímo s objekty BIM vedle Revitu
    • Zaškrtnutí 2 GB cloudové úložiště – ukládejte svůj obsah Revitu
    • Zaškrtnutí Získejte posouzení životního cyklu (A1–A3) uhlíku zabudovaného přímo z Revitu