Publikovat produkty
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer
    Wilkins

    Wilkins 975XL2 (3/4" -2") Reduced Pressure Principle Backflow Preventer

    The Reduced Pressure Principle Backflow Preventer shall be certified to NSF/ANSI/CAN 61 and 372, shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The assembly shall be configurable to include a sensor to monitor excessive water discharge from the relief valve for flood detection. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL2.

    Features:

    • Easy access to first check simplifies debris removal
    • Repair kit allows for a quick fix instead of a full replacement
    • Entire unit serviceable in line
    • Stainless steel shutoff handles are corrosion resistant
    • Wye pattern design provides separate access to checks and relief valve for reduced labor costs

    Keywords: Backflow Preventer, hazard protection, Reduced Pressure Principle, Zurn Wilkins 975XL2, Reduced Pressure Principle Backflow Preventer, Reduced Pressure Backflow Preventer, relief valve, check valve, reduced pressure principle backflow prevention assembly, reduced pressure zone backflow preventer, backflow relief valve, backflow pressure relief valve, zurn 975xl2, wilkins zurn 975xl2

    Technická specifikace
    • Jedinečná ref. hodnotazurn-975xl2-075-2
    • Skupina výrobkůBackflow Preventers
    • Skupina produktůReduced Pressure Principle Assembly
    • TypObjekt
    • Datum zveřejnění2025-09-02
    • Číslo vydání1
    • Výška (palce)8.5
    • Šířka (palce)6.5
    • Hloubka (palce)12
    Související
    • Hlavní materiálBronze
    • Navrženo vSpojené státy americké
    • Čistá hmotnost (lb)12
    Klasifikace
    • Kategorie objektu BIMInstalace - Ventily
    • Klasifikace IFCVentil
    • Kód Uniclass 2015Pr_65_54_94_72
    • Popis Uniclass 2015Reduced pressure zone valves
    • Kód CSI MasterFormat 201440 05 67
    • Název CSI MasterFormat 2014Specialized Pressure and Flow-Control Valves
    • Číslo OmniClass23-27 31 47
    • Název OmniClassPressure Regulating Valves

    Dostupnost regionu

    Severní Amerika
    Anguilla
    Antigua a Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudské ostrovy
    Britské Panenské ostrovy
    Curaçao
    Dominika
    Dominikánská republika
    Gaudeloupe
    Grenada
    Grónsko
    Guatemala
    Haiti
    Honduras
    Jamajka
    Kajmanské ostrovy
    Kanada
    Karibské Nizozemsko
    Kostarika
    Kuba
    Martinik
    Mexiko
    Montserrat
    Nikaragua
    ostrovy Turks a Caicos
    Panama
    Pannenske Ostrovy
    Portoriko
    Saint-Pierre a Miquelon
    Salvador
    Spojené státy americké
    Svatá Lucie
    Svatý Bartoloměj
    Svatý Kryštof a Nevis
    Svatý Martin
    Svatý Martin
    Svatý Vincenc a Grenadiny
    Trinidad a Tobago
    Common.Footer.ValueProp.Image.AltText

    Design App pro Revit

    Načtěte rodiny přímo do svého modelu Revit jedním kliknutím

    Získejte místo pro snadnější přístup k novým objektům, ukládejte své rodiny Revit a spolupracujte se svým týmem.

    • ZaškrtnutíPracujte přímo s objekty BIM vedle Revitu
    • Zaškrtnutí 2 GB cloudové úložiště – ukládejte svůj obsah Revitu
    • Zaškrtnutí Získejte posouzení životního cyklu (A1–A3) uhlíku zabudovaného přímo z Revitu