Publikovat produkty
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
Wilkins 950XL3BFSS Double Check Backflow Preventer
    Wilkins

    Wilkins 950XL3BFSS Double Check Backflow Preventer

    The Double Check Type Backflow Preventer shall be certified to NSF/ANSI/CAN 61, rated to 180°, and supplied with UL/FM approved butterfly valves with supervisory switch. The main body and access covers shall be low lead bronze (ASTMB 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first andsecond check shall be located at an angle and accessible for maintenance from the top of the device, without removing thedevice from the line. The checks shall share a single access cover and the test cocks shall be accessible from the top ofthe device. The Double Check Type Backflow Preventer shall be a WILKINS Model 950XL3BFSS.

    Compliance:

    • NSFStandard61
    • NSFStandard372
    • ASSEStandards
    • UPC
    • UL
    • IPC
    • NPCC
    • USC Confirmed

    Features:

    • Ideal for use where Lead Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential non-health hazard exists. Features slow closing resilient seated UL/FM approved butterfly shutoffs with supervisory switch. For indoor or outdoor use.
    • Sizes 1 1/4", 1 1/2", 2"
    • Minimum working water pressure: 20 PSI
    • Maximum working water pressure: 175 PSI
    • Minimum working water temperature: 33°F
    • Maximum working water temperature: 180°F
    • Hydrostatic test pressure: 350 PSI
    • End connections Threaded: (FNPT) ANSI B1.20.1

    keywords: Double Check Backflow Preventer, Zurn 950XL3BFSS, double check backflow preventer, potable water backflow valve, Zurn bronze backflow assembly,112-950XL3BFSS,114-950XL3BFSS,2-950XL3BFSS

    Technická specifikace
    • Jedinečná ref. hodnota950XL3BFSS
    • Skupina výrobkůBackflow Preventers
    • Skupina produktůDouble Check Assembly
    • TypObjekt
    • Datum zveřejnění2025-10-23
    • Číslo vydání1
    • Výška (palce)7.68
    • Šířka (palce)6
    • Hloubka (palce)15.67
    Související
    • Hlavní materiálBronze
    • Navrženo vSpojené státy americké
    • Čistá hmotnost (lb)18
    Klasifikace
    • Kategorie objektu BIMInstalace - Ventily

    Dostupnost regionu

    Severní Amerika
    Anguilla
    Antigua a Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudské ostrovy
    Britské Panenské ostrovy
    Curaçao
    Dominika
    Dominikánská republika
    Gaudeloupe
    Grenada
    Grónsko
    Guatemala
    Haiti
    Honduras
    Jamajka
    Kajmanské ostrovy
    Kanada
    Karibské Nizozemsko
    Kostarika
    Kuba
    Martinik
    Mexiko
    Montserrat
    Nikaragua
    ostrovy Turks a Caicos
    Panama
    Pannenske Ostrovy
    Portoriko
    Saint-Pierre a Miquelon
    Salvador
    Spojené státy americké
    Svatá Lucie
    Svatý Bartoloměj
    Svatý Kryštof a Nevis
    Svatý Martin
    Svatý Martin
    Svatý Vincenc a Grenadiny
    Trinidad a Tobago
    Common.Footer.ValueProp.Image.AltText

    Design App pro Revit

    Načtěte rodiny přímo do svého modelu Revit jedním kliknutím

    Získejte místo pro snadnější přístup k novým objektům, ukládejte své rodiny Revit a spolupracujte se svým týmem.

    • ZaškrtnutíPracujte přímo s objekty BIM vedle Revitu
    • Zaškrtnutí 2 GB cloudové úložiště – ukládejte svůj obsah Revitu
    • Zaškrtnutí Získejte posouzení životního cyklu (A1–A3) uhlíku zabudovaného přímo z Revitu