Publikovat produkty
UltraTouch - Natural Cotton Fiber Insulation
UltraTouch - Natural Cotton Fiber Insulation

    UltraTouch - Natural Cotton Fiber Insulation

    UltraTouch™ Recycled Denim Insulation
    High-Performance Acoustical and Thermal Insulation with Sustainable Impact

    UltraTouch™ is a safe, sustainable batt insulation made from 80% post-consumer recycled denim and cotton fibers. Unlike fiberglass or foam, it’s non-toxic, non-itch, and free from VOCs or chemical irritants—making it safe to handle and install without protective equipment or warning labels.

    Manufactured with a patented production process, UltraTouch™ delivers exceptional sound absorption and thermal performance. Its dense, 3D fiber structure traps and controls sound waves, making it ideal for acoustic-sensitive spaces. It offers high NRC values and superior R-value performance for walls, ceilings, and attics.

    Performance Highlights:

    • Excellent Acoustic Control: High NRC to reduce airborne sound (traffic, HVAC, voices).
    • Superior Thermal Efficiency: Tight friction fit with oversized batts for optimal coverage.
    • Safe & Non-Toxic: No fiberglass, formaldehyde, or VOCs—safe for occupants and installers.
    • Fire & Mold Resistant: Class A fire-rated, treated with a boron-based fire retardant and fungal inhibitor.
    • Sustainable: Made from 80% post-consumer denim; 100% recyclable with low-energy manufacturing.

    UltraTouch meets ASTM standards for commercial and residential use and passes California’s rigorous Section 01350 IAQ standard—making it a top choice for healthy, sustainable buildings.

    Specifikace
    • SECTION 07 21 16

      UltraTouchTM Insulation

      PART 1 GENERAL

      1. SECTION INCLUDES
        1. UltraTouchTMinsulation.
      2. REFERENCES
        1. American Society for Testing and Materials (ASTM)
          1. ASTM C423: Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.
          2. ASTM E84: Standard Test Method for Surface Burning Characteristics of Building Materials.
          3. ASTM E795: Standard Practices for Mounting Test Specimens During Sound Absorption Tests
        2. International Code Council (ICC)
          1. ICC IBC: International Building Code
      3. SUBMITTALS
        1. Product Data: Manufacturer’s data sheet and installation instructions.
        2. Samples: Submit, at minimum, a 4” x 4” sample for each type of specified insulation.
        3. Test Reports: Upon request, submit certified test reports to verify specified product performance.
      4. QUALITY ASSURANCE
        1. Qualifications:
          1. Manufacturers: Provide acoustical insulation from a single manufacturer.
          2. Installers: Utilize an installer having demonstrated experience on projects of comparable size and complexity.
        2. Performance Requirements:
          1. Surface Burning Characteristics: Acoustical product to perform as specified when tested in accordance with ASTM E84. Acoustical products surface burning performance should comply with the International Building Code and other local building code requirements.
      5. DELIVERY, STORAGE, AND HANDLING
        1. Storage and Handling Requirements:
          1. Handle insulation carefully to avoid any damage.
          2. Store insulation indoors in a clean, cool, dry place, and out of direct sunlight.
          3. Store insulation in a space where the ambient temperature and humidity conditions are being maintained at the levels indicated for the project when occupied for its intended use.
      6. SITE CONDITIONS
        1. Ambient Conditions:
          1. Maintain ambient temperature and humidity conditions at levels indicated for the project when occupied for its intended use.
          2. Do not install insulation under environmental conditions outside manufacturer’s recommended limits.
        2. Existing Conditions: Do not install insulation until space is enclosed and weather proofed, and wet work is completely dry.
      7. WARRANTY
        1. Provide manufacturer’s written product warranty per Section 01 77 00 – Closeout Procedures.

      PART 2 PRODUCTS

      (Specifier Note: Red colored text below requires you to select an option before this specification can be completed. Options in red text are bound by parenthesis. Additional UltraTouch information can be found on our website: www.acousticalsurfaces.com

      1. MANUFACTURERS
        1. Acoustical Surfaces, Inc., 123 Columbia Court N, Chaska, MN 55318.
          Phone: 952-448-5300. Fax: 952-448-2613. Website: www.acousticalsurfaces.com
      2. DESCRIPTION
        1. Product: UltraTouchTM insulation by Acoustical Surfaces, Inc.
        2. Product Options:
          1. Panel Composition: Thermally bonded natural cotton fiber insulation
          2. Panel Thickness: (3.5”) / (5.5”)

      Nominal Batt Size: (16”) / (24”) width x 94” length

      1. Mounting Method: In-Wall Between Studs

      PART 3 EXECUTION

      1. EXAMINATION
      2. Verification of Conditions:
      3. All wet work in the installation area must be complete, cured, and dry prior to installation.
      4. INSTALLATION
      5. Comply with manufacturer’s instructions and recommendations for installation of installation and with industry standards.
      6. PROTECTION
      7. Protect installed work from damage due to subsequent construction activity, including temperature and humidity limitations and dust control, so that the work will be without damage and deterioration at the time of acceptance by the owner.

      END OF SECTION

    Technická specifikace
    • Jedinečná ref. hodnotaacoustical-surfaces-ultratouch
    • Skupina výrobkůSlab and Board Thermal Insulation
    • Skupina produktůWall Insulation
    • TypObjekt
    • Datum zveřejnění2011-04-21
    • Číslo vydání1
    Související
    • Navrženo vSpojené státy americké
    • Vyrobeno vSpojené státy americké
    Klasifikace
    • Kategorie objektu BIMStavební materiály - Izolace
    • Klasifikace IFCStrop
    • Kód Uniclass 2015Ss_30_25_22_01
    • Popis Uniclass 2015Acoustic baffle suspended ceiling systems
    • Kód CSI MasterFormat 201409 84 00
    • Název CSI MasterFormat 2014Acoustic Room Components
    • Číslo OmniClass23-15 13 21 35
    • Název OmniClassAcoustical Ceiling Treatment
    • Kód CSI UniFormat IIC30
    • Název CSI UniFormat IIINTERIOR FINISHES

    Dostupnost regionu

    Severní Amerika
    Anguilla
    Antigua a Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudské ostrovy
    Britské Panenské ostrovy
    Curaçao
    Dominika
    Dominikánská republika
    Gaudeloupe
    Grenada
    Grónsko
    Guatemala
    Haiti
    Honduras
    Jamajka
    Kajmanské ostrovy
    Kanada
    Karibské Nizozemsko
    Kostarika
    Kuba
    Martinik
    Mexiko
    Montserrat
    Nikaragua
    ostrovy Turks a Caicos
    Panama
    Pannenske Ostrovy
    Portoriko
    Saint-Pierre a Miquelon
    Salvador
    Spojené státy americké
    Svatá Lucie
    Svatý Bartoloměj
    Svatý Kryštof a Nevis
    Svatý Martin
    Svatý Martin
    Svatý Vincenc a Grenadiny
    Trinidad a Tobago